Evidence map›Paper›PMID 38305815›Full record

ArticleMedical & biological engineering & computing2024

A multimodal virtual vision platform as a next-generation vision system for a surgical robot.

Young Gyun Kim, Jong Hyeon Lee, Jae Woo Shim, Wounsuk Rhee, Byeong Soo Kim, Dan Yoon, Min Jung Kim, Ji Won Park, Chang Wook Jeong, Han-Kwang Yang and 2 more

Abstract read
In one paragraph

Article in Medical & biological engineering & computing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Young Gyun Kim *Interdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro, Gwanak-Gu, Seoul, 08826, Republic of Korea.
Jong Hyeon Lee *Interdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro, Gwanak-Gu, Seoul, 08826, Republic of Korea.
Jae Woo ShimInterdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro, Gwanak-Gu, Seoul, 08826, Republic of Korea.
Wounsuk RheeSeoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea.
Byeong Soo KimInterdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro, Gwanak-Gu, Seoul, 08826, Republic of Korea.
Dan YoonInterdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro, Gwanak-Gu, Seoul, 08826, Republic of Korea.
Min Jung KimDepartment of Surgery, Seoul National University College of Medicine, 103 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea.
Ji Won ParkDepartment of Surgery, Seoul National University College of Medicine, 103 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea.
Chang Wook JeongDepartment of Urology, Seoul National University College of Medicine, 103 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea.
Han-Kwang YangDepartment of Surgery, Seoul National University College of Medicine, 103 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea.
Minwoo ChoDepartment of Transdisciplinary Medicine, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea. chovis@snuh.org.
Sungwan KimDepartment of Biomedical Engineering, Seoul National University College of Medicine, 103 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea. sungwan@snu.ac.kr.ORCID http://orcid.org/0000-0002-9318-849X

Funding

Korea Medical Device Development Fund 1711174462Korea Medical Device Development Fund 1711179421Korea Medical Device Development Fund RS-2020-KD000123Korea Medical Device Development Fund RS-2021-KD000006Ministry of Health & Welfare HI19C1352Seoul National University 800-20230385Seoul National University Hospital 1920230020
6 · The paper itself

Abstract

Robot-assisted surgery platforms are utilized globally thanks to their stereoscopic vision systems and enhanced functional assistance. However, the necessity of ergonomic improvement for their use by surgeons has been increased. In surgical robots, issues with chronic fatigue exist owing to the fixed posture of the conventional stereo viewer (SV) vision system. A head-mounted display was adopted to alleviate the inconvenience, and a virtual vision platform (VVP) is proposed in this study. The VVP can provide various critical data, including medical images, vital signs, and patient records, in three-dimensional virtual reality space so that users can access medical information simultaneously. An availability of the VVP was investigated based on various user evaluations by surgeons and novices, who executed the given tasks and answered questionnaires. The performances of the SV and VVP were not significantly different; however, the craniovertebral angle of the VVP was 16.35° higher on average than that of the SV. Survey results regarding the VVP were positive; participants indicated that the optimal number of displays was six, preferring the 2 × 3 array. Reflecting the tendencies, the VVP can be a neoconceptual candidate to be customized for medical use, which opens a new prospect in a next-generation surgical robot.

Indexed as

RoboticsRobotic Surgical ProceduresVirtual RealityHumansUser-Computer InterfaceVision, Ocularda Vinci research kitHead-mounted displayUsabilityUser evaluationVirtual vision platform

Identifiers

PMID38305815
PMCPMC11021270

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.