Channelized hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom: Part II. Repeatability study.

Mingdong Fan, Zhongxing Zhou, Cynthia McCollough, Lifeng Yu

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Mingdong FanDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Zhongxing ZhouDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Cynthia McColloughDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Lifeng YuDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Mayo Clinic · US

Funding

Trade-offs in human observer performance, image quality metrics, and patient doseR01EB017095 · NIBIB · MAYO CLINIC ROCHESTER · PI Hao Gong, Cynthia H McCollough · 2012 to 2026
$7.0M
Dissemination of a Software Platform for Efficient CT Radiation Dose Optimization and Diagnostic Performance AssessmentU24EB028936 · NIBIB · MAYO CLINIC ROCHESTER · PI YU, LIFENG · 2019 to 2023
$1.6M
NIBIB NIH HHS R01 EB017095NIBIB NIH HHS U24 EB028936NIH HHS R01EB017095NIH HHS U24EB028936
6 · The paper itself

Abstract

backgroundObjective and quantitative evaluation for low-contrast detectability that correlates with human observer performance is lacking for routine CT quality control testing. Channelized Hotelling observer (CHO) is considered a strong candidate to fill the need but has long been deemed impractical to implement due to its requirement of a large number of repeated scans in order to provide accurate and precise estimates of index of detectability (d'). In our previous work, we optimized a CHO model observer on the American College of Radiology (ACR) CT accreditation phantom and achieved accurate measurement of d' with only 1-3 repeat scans. PURPOSE: In this work, we aim to validate the repeatability of the proposed CHO-based low-contrast evaluation on four scanner models using the ACR CT accreditation phantom.

methodsThe repeatability test was performed on four different scanners from two major CT manufacturers: Siemens Force and Alpha; Canon Prism and Prime SP. An ACR CT phantom was scanned 10 times, each time after repositioning of the phantom. For each repositioning, 3 repeated scans were acquired at 24, 12, and 6 mGy on all four scanner models. CHO was applied at the measured dose levels for different low-contrast object sizes (4-6 mm). The CHO was also applied to images created using deep learning-based reconstructions on Canon Prism and to four different scan/reconstruction modes on the Siemens Alpha, a photon-counting-detector (PCD)-CT. The repeatability was evaluated by the probability that a measurement would fall within the ±15% tolerance (P

resultsWith the CHO setting optimized for the ACR phantom and the use of 3 repeated scans and 9 non-overlapping slices per scan, the CHO measurement could provide high repeatability with P

conclusionThe CHO provided highly repeatable measurements with over 95% probability that a CHO measurement would lie within the ±15% tolerance for most of the dose levels and object sizes on the ACR phantom. The repeatability was maintained when the CHO was applied to images created with a commercial deep learning-based reconstruction and various scan/reconstruction modes on a PCD-CT. This study demonstrates that practical implementation of CHO for routine quality control and performance evaluation is feasible.

Indexed as

AccreditationTomography, X-Ray ComputedAlgorithmsHumansImage Processing, Computer-AssistedPhantoms, ImagingRadiation Dosagecomputed tomography (CT)image qualitymodel observerquality controlradiation dose

Identifiers

PMID38305692
PMCPMC10939955
OpenAlexW4391473103

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.