Evidence map›Paper›PMID 38304714›Full record

ArticleBMJ open sport & exercise medicine2024

Head Exposure to Acceleration Database in Sport (HEADSport): a kinematic signal processing method to enable instrumented mouthguard (iMG) field-based inter-study comparisons.

Gregory Tierney, Steven Rowson, Ryan Gellner, David Allan, Sadaf Iqbal, Pardis Biglarbeigi, James Tooby, James Woodward, Amir Farokh Payam

Abstract read
In one paragraph

Article in BMJ open sport & exercise medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Gregory TierneyNanotechnology and Integrated Bioengineering Centre (NIBEC), Ulster University, Belfast, UK.ORCID 0000-0002-4666-4473
Steven RowsonBiomedical Engineering and Mechanics, Virginia Tech, Blacksburg, Virginia, USA.
Ryan GellnerBiomedical Engineering and Mechanics, Virginia Tech, Blacksburg, Virginia, USA.
David AllanNanotechnology and Integrated Bioengineering Centre (NIBEC), Ulster University, Belfast, UK.
Sadaf IqbalSport and Exercise Sciences Research Institute, Ulster University, Belfast, UK.
Pardis BiglarbeigiSchool of Science and Engineering, University of Dundee, Dundee, UK.
James ToobyCarnegie Applied Rugby Research (CARR) Centre, Carnegie School of Sport, Leeds Beckett University, Leeds, UK.
James WoodwardSport and Exercise Sciences Research Institute, Ulster University, Belfast, UK.
Amir Farokh PayamNanotechnology and Integrated Bioengineering Centre (NIBEC), Ulster University, Belfast, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Instrumented mouthguard (iMG) systems use different signal processing approaches limiting field-based inter-study comparisons, especially when artefacts are present in the signal. The objective of this study was to assess the frequency content and characteristics of head kinematic signals from head impact reconstruction laboratory and field-based environments to develop an artefact attenuation filtering method (HEADSport filter method). Methods: Laboratory impacts (n=72) on a test-dummy headform ranging from 25 to 150 g were conducted and 126 rugby union players were equipped with iMGs for 209 player-matches. Power spectral density (PSD) characteristics of the laboratory impacts and on-field head acceleration events (HAEs) (n=5694) such as the 95th percentile cumulative sum PSD frequency were used to develop the HEADSport method. The HEADSport filter method was compared with two other common filtering approaches (Butterworth-200Hz and CFC180 filter) through signal-to-noise ratio (SNR) and mixed linear effects models for laboratory and on-field events, respectively. Results: The HEADSport filter method produced marginally higher SNR than the Butterworth-200Hz and CFC180 filter and on-field peak linear acceleration (PLA) and peak angular acceleration (PAA) values within the magnitude range tested in the laboratory. Median PLA and PAA (and outlier values) were higher for the CFC180 filter than the Butterworth-200Hz and HEADSport filter method (p<0.01). Conclusion: The HEADSport filter method could enable iMG field-based inter-study comparisons and is openly available at https://github.com/GTBiomech/HEADSport-Filter-Method.

Indexed as

ConcussionFilteringHeadRugby

Identifiers

PMID38304714
PMCPMC10831454

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.