Evidence map›Paper›PMID 38304220›Full record

ArticleClinics in orthopedic surgery2024

Optimization of Acetabular Cup Abduction by Adjusting Pelvic Pitch.

Jung-Wee Park, Jae-Hyun Park, Hong-Seok Kim, Young-Kyun Lee, Kye-Young Han, Yong-Chan Ha, Kyung-Hoi Koo

Abstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jung-Wee ParkDepartment of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.ORCID https://orcid.org/0000-0002-4515-1895
Jae-Hyun ParkDepartment of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.ORCID https://orcid.org/0000-0003-1469-4325
Hong-Seok KimDepartment of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.ORCID https://orcid.org/0000-0002-9524-7019
Young-Kyun LeeDepartment of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.ORCID https://orcid.org/0000-0001-6564-4294
Kye-Young HanDepartment of Orthopaedic Surgery, Welton Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0002-3574-2608
Yong-Chan HaDepartment of Orthopaedic Surgery, Chung-Ang University Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0002-6249-0581
Kyung-Hoi KooDepartment of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.ORCID https://orcid.org/0000-0001-5251-2911

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The purposes of this study were to determine the accuracy of our cup positioning method and to evaluate the dislocation rate after total hip arthroplasty (THA). Methods: After positioning the patient in the lateral decubitus position on the operation table, an anteroposterior view of the hip was taken. The pelvic pitch was measured on the X-ray. A positive pitch was defined as the caudal rotation of the upper hemipelvis. Our target abduction of the cup was 43°. We used the cup holder to guesstimate the cup abduction. In a preliminary study, we found that the weight of the cup holder increased the pelvic pitch by 5°. Thus, the target abduction of the cup holder was calculated by a formula: 43° - pelvic pitch - 5°. During the cup insertion, the cup holder was anteverted to the calculated target according to the concept of combined anteversion. We evaluated 478 THAs (429 patients), which were done with the use of the method. Results: The mean cup abduction was 43.9° (range, 32.0°-53.0°) and the mean error of cup abduction was 2.4° (standard deviation [SD], 2.0°; range, 0.0°-11.0°). The mean cup anteversion was 28.5° (range, 10.0°-42.0°) and the mean error of cup anteversion was 6.7° (SD, 5.2°; range, 0.0°-27.6°). Of all, 82.4% of the cups (394 / 478) were within the safe zone: 30°-50° abduction and 10°-35° anteversion. During 2- to 5-year follow-up, no hip dislocated. Conclusions: Our adjusting method according to the pelvic pitch can be a reliable option for optimizing the cup abduction in THA.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisJoint DislocationsAcetabulumHumansMovementRadiographyCup positionPelvic pitchTotal hip arthroplastyTreatment

Identifiers

PMID38304220
PMCPMC10825242

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.