Accuracy and efficiency of a calibration approach in dynamic navigation for implant placement: An in vitro study.

Xiyan Pei, Jinlong Weng, Feng Sun, Yu Ma, Siniong Iao, Xiaoqiang Liu

Abstract read
In one paragraph

Article in Journal of dental sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiyan PeiFirst Clinic Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China.
Jinlong WengFirst Clinic Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China.
Feng SunFirst Clinic Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China.
Yu MaFirst Clinic Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China.
Siniong IaoDepartment of Periodontology, Peking University School and Hospital of Stomatology, Beijing, China.
Xiaoqiang LiuDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/purpose: Computer-assisted dynamic navigation surgery could provide accurate implant placement. However, its low efficiency was always criticized by dental surgeons. The purpose of this study was to evaluate the accuracy and efficiency of a calibration approach with reflective wafers in dynamic navigation for implant placement. Materials and methods: Eighty implants were placed in the standardized polyurethane mandibular models under dynamic navigation and divided into 2 groups according to the calibration methods (n = 40). The U-shaped tube (UT) group used a prefabricated U-shaped tube embedded with radiopaque markers. The reflective wafers (RW) group used a fixation with 3 round reflective wafers as markers. Postoperative cone beam computed tomography images were obtained for implants deviation analyses. The calibration time was used to evaluate the efficiency of the 2 methods. Results: Significant differences were found in the trueness and efficiency between the 2 groups ( Conclusion: The calibration method of RW improved the efficiency significantly and achieved equivalent trueness with UT for dynamic navigation during implant placement.

Indexed as

AccuracyDynamic navigationImplant surgery

Identifiers

PMID38303864
PMCPMC10829622

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.