Evidence map›Paper›PMID 38303808›Full record

ArticleJournal of dental sciences2024

Effect of different implant locations and abutment types on stress and strain distribution under non-axial loading: A 3-dimensional finite element analysis.

Didem Sakar, Mustafa Baris Guncu, Hale Arikan, Mehmet Muhtarogullari, Guliz Aktas, Natalia Reiss, Ilser Turkyilmaz

Open access · goldAbstract read
In one paragraph

Article in Journal of dental sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Didem SakarDepartment of Prosthodontics, School of Dentistry, Hacettepe University, Ankara, Turkey.
Mustafa Baris GuncuDepartment of Prosthodontics, School of Dentistry, Hacettepe University, Ankara, Turkey.
Hale ArikanDepartment of Prosthodontics, Faculty of Dentistry, Baskent University, Ankara, Turkey.
Mehmet MuhtarogullariDepartment of Prosthodontics, School of Dentistry, Hacettepe University, Ankara, Turkey.
Guliz AktasDepartment of Prosthodontics, School of Dentistry, Hacettepe University, Ankara, Turkey.
Natalia ReissNew York University College of Dentistry, New York, NY, USA.
Ilser TurkyilmazDepartment of Prosthodontics, New York University College of Dentistry, New York, NY, USA.
Hacettepe University · TRNew York University · USBaşkent University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/purpose: Dental implants have been a popular treatment for replacing missing teeth. The purpose of this study was to investigate the impact of engaging (hexagonal) and non-engaging (non-hexagonal) abutments in various six-unit fixed prosthesis on the stress distribution and loading located in the implant neck, implant abutment, and surrounding bone. Materials and methods: Three implants were digitally designed and inserted parallel to each other in edentulous sites of the maxillary right canine, maxillary right central incisor, and maxillary left canine. Titanium base engaging abutments, non-engaging abutments and connecting screws were designed. Five distinct models of 6-unit fixed dental prosthesis were created, each featuring different combinations of various abutments. Forces (45-degree angle) were applied to the prosthesis, allowing for the analysis of the stress distribution on the implant neck and abutments, and the maximum and minimum principal stress values on the cortical and trabecular bone. Results: Von Mises stress values and stress distributions located in the implant neck region due to the applied loading forces were analyzed. The overall stress values were highest while employing the hexagonal abutments. The maxillary left canine with a hexagonal abutment (model 5) reported the highest von mises value (64.71 MPa) while the maxillary right canine with a non-hexagonal abutment (model 4) presented lowest von mises value (56.69 MPa). Conclusion: The results suggest that both the various abutment combinations (engaging and non-engaging) on five different models have a similar influence on the distribution of stress within the implant system.

Indexed as

AbutmentFinite elementImplantStrainStress

Identifiers

PMID38303808
PMCPMC10829709
OpenAlexW4388586615

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.