Evidence map›Paper›PMID 38300484›Full record

ArticleJournal of fluorescence2025

On-Off-On Fluorometric Detection of Hg(II) and L-Cysteine Using Red Emissive Nitrogen-Doped Carbon Dots for Environmental and Clinical Sample Analysis.

D James Nelson, N Vasimalai, S Abraham John, M G Sethuraman

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of fluorescence, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

D James NelsonDepartment of Chemistry, The Gandhigram Rural Institute-Deemed to be University, Gandhigram, Dindigul, 624302, Tamilnadu, India.
N VasimalaiDepartment of Chemistry, B.S. Abdur Rahman Crescent Institute of Science and Technology, Vandalur, Chennai, 600048, Tamilnadu, India.
S Abraham JohnDepartment of Chemistry, The Gandhigram Rural Institute-Deemed to be University, Gandhigram, Dindigul, 624302, Tamilnadu, India. abrajohn@gmail.com.
M G SethuramanDepartment of Chemistry, The Gandhigram Rural Institute-Deemed to be University, Gandhigram, Dindigul, 624302, Tamilnadu, India. mgsethu@gmail.com.
Gandhigram Rural Institute · INB.S. Abdur Rahman Crescent Institute of Science & Technology · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This research introduces a novel fluorescence sensor 'on-off-on' employing nitrogen-doped carbon dots (N-CDs) with an 'on-off-on' mechanism for the selective and sensitive detection of Hg(II) and L-cysteine (L-Cys). N-CDs was synthesized using citric acid as the carbon precursor and urea as the nitrogen source in dimethylformamide (DMF) solvent, resulting in red emissive characteristics under UV light. Comprehensive spectroscopic analyses, including UV-Vis, fluorescence, FT-IR, XRD, XPS, Raman, and Zeta potential techniques, validated the structural and optical characteristics of the synthesized N-CDs. The maximum excitation and emission of N-CDs were observed at 548 and 622 nm, respectively. The quantum yield of N-CDs was calculated to be 16.1%. The fluorescence of N-CDs effectively quenches upon the addition of Hg(II) due to the strong coordination between Hg(II) and the surface functionalities of N-CDs. Conversely, upon the subsequent addition of L-Cys, the fluorescence of N-CDs was restored. This restoration can be attributed to the stronger affinity of the -SH group in L-Cys towards Hg(II) relative to the surface functionalities of N-CDs. This dual-mode response enabled the detection of Hg(II) and L-Cys with impressive detection limits of 15.1 nM and 8.0 nM, respectively. This sensor methodology effectively detects Hg(II) in lake water samples and L-Cys levels in human urine, with a recovery range between 99 and 101%. Furthermore, the N-CDs demonstrated excellent stability, high sensitivity, and selectivity, making them a promising fluorescence on-off-on probe for both environmental monitoring of Hg(II) and clinical diagnostics of L-Cys.

Indexed as

CarbonCysteineFluorescent DyesFluorometryMercuryNitrogenQuantum DotsHumansLimit of DetectionSpectrometry, FluorescenceCarbonCysteineFluorescent DyesMercuryNitrogenCarbon dotsHg(II) DetectionL-cysteine DetectionOn-off-on Fluorescence SensorRed Emissive CDs

Identifiers

PMID38300484
OpenAlexW4391441740

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.