Evidence map›Paper›PMID 38299102›Full record

ArticleData in brief2024

Geometric data of commercially available tricuspid valve annuloplasty devices.

Collin E Haese, Mrudang Mathur, Marcin Malinowski, Tomasz A Timek, Manuel K Rausch

Open access · goldAbstract read
In one paragraph

Article in Data in brief, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Collin E HaeseWalker Department of Mechanical Engineering, The University of Texas at Austin, 204 E Dean Keeton St, Austin, 78712, TX, USA.
Mrudang MathurWalker Department of Mechanical Engineering, The University of Texas at Austin, 204 E Dean Keeton St, Austin, 78712, TX, USA.
Marcin MalinowskiDepartment of Cardiac Surgery, Medical University of Silesia in Katowice, 15 Poniatowskiego, 40-055 Katowice, Poland.
Tomasz A TimekDivision of Cardiothoracic Surgery, Spectrum Health, 221 Michigan St NE, Suite 300, Grand Rapids, 49503, MI, USA.
Manuel K RauschWalker Department of Mechanical Engineering, The University of Texas at Austin, 204 E Dean Keeton St, Austin, 78712, TX, USA.
Walker (United States) · USSpectrum Health · US

Funding

Using an Electrospun Surrogate Model to Investigate Mechanisms of Tricuspid Valve MaladaptationR01HL165251 · NHLBI · UNIVERSITY OF TEXAS AT AUSTIN · PI MANUEL Karl RAUSCH · 2022 to 2026
$4.3M
Human-Specific Prediction, Training, and Visualization Tools for the Tricuspid Valve from Existing DataR21HL161832 · NHLBI · UNIVERSITY OF TEXAS AT AUSTIN · PI RAUSCH, MANUEL KARL · 2022 to 2023
$222k
American Heart Association-American Stroke Association 18CDA34120028NHLBI NIH HHS R01 HL165251NHLBI NIH HHS R21 HL161832
6 · The paper itself

Abstract

Tricuspid valve annuloplasty is the gold standard surgical treatment for functional tricuspid valve regurgitation. During this procedure, ring-like devices are implanted to reshape the diseased tricuspid valve annulus and to restore function. For the procedure, surgeons can choose from multiple available device options varying in shape and size. In this article, we provide the three-dimensional (3D) scanned geometry (*.stl) and reduced midline (*.vtk) of five different annuloplasty devices of all commercially available sizes. Three-dimensional images were captured using a 3D scanner. After extracting the surface geometry from these images, the images were converted to 3D point clouds and skeletonized to generate a 3D midline of each device. In total, we provide 30 data sets comprising the Edwards Classic, Edwards MC3, Edwards Physio, Medtronic TriAd, and Medtronic Contour 3D of sizes 26-36. This dataset can be used in computational models of tricuspid valve annuloplasty repair to inform accurate repair geometry and boundary conditions. Additionally, others can use these data to compare and inspire new device shapes and sizes.

Indexed as

AnnulusDownsizingMicro-computed tomographyRepairThree-dimensional scan

Identifiers

PMID38299102
PMCPMC10828561
OpenAlexW4390724743

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.