ArticleFrontiers in neurology2024
Risk factors and management of intraprocedural rupture during coil embolization of unruptured intracranial aneurysms: role of balloon guiding catheter.
Article in Frontiers in neurology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it, 10 citations in OpenAlex.
- Intra-procedural re-rupture during endovascular coiling of ruptured intracranial aneurysms: a systematic review.Neuroradiology · 2026Pooled it
- A meta-analytic insight into predictors and consequences of intra-procedural rupture in unruptured intracranial aneurysms.Neurosurgical review · 2025Pooled it
- Impact of Provider Volume on Intraprocedural Rupture Risk During Endovascular Treatment of Ruptured Intracranial Aneurysms: A Systematic Review and Meta-Analysis.Life (Basel, Switzerland) · 2026Review
- Case Report: Hemorrhagic-Thrombotic Escalation After Intraprocedural Rupture During Stent-Assisted Coiling: A Case-Based Narrative Review and Staged Communication Model.Journal of clinical medicine · 2026Article
- Evaluation of bail-out techniques for managing cerebral vessel perforation: An experimental study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- A novel peel-away sheath technique for sheathless transradial use of 8 Fr balloon guide catheter.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Preliminary Experience With Novel Straight 3-Fr Guiding Sheath for Transradial Access in Endovascular Treatment: Feasibility and Safety.Operative neurosurgery (Hagerstown, Md.) · 2025Article
- Turn-Over Technique Using a Balloon Guiding Catheter for Stable Transfemoral Neuroendovascular Therapy in Type III Aortic Arch with Severe Vessel Tortuosity.Journal of neuroendovascular therapy · 2025Article
- Intermediate catheter use is associated with intraprocedural rupture during coil embolization of ruptured intracranial aneurysms: a retrospective propensity score-matched study.Frontiers in neurology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Intraprocedural rupture (IPR) is a serious complication of endovascular coil embolization of unruptured intracranial aneurysms (UIAs). Although outcomes after IPR are poor, methods to prevent subsequent neurological deterioration have not yet been investigated. We evaluated the risk factors and management strategies for IPR, particularly the role of balloon guiding catheters (BGCs) in rapid hemostasis. Methods: We retrospectively reviewed all UIA cases treated with coil embolization at three institutions between 2003 and 2021, focusing on preoperative radiological data, operative details, and outcomes. Results: In total, 2,172 aneurysms were treated in 2026 patients. Of these, 19 aneurysms in 19 patients (0.8%) ruptured during the procedure. Multivariate analysis revealed that aneurysms with a bleb (OR: 3.03, 95% CI: 1.21 to 7.57, Discussion: The incidence of IPR was relatively low. A bleb, small aneurysm neck, and location on PcomA and AcomA are independent risk factors for IPR. The use of BGC may prevent fatal clinical deterioration and achieve better clinical outcomes in patients with IPR.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.