Evidence map›Paper›PMID 38298866›Full record

ArticleNeurophotonics2024

Resolution-enhanced multi-core fiber imaging learned on a digital twin for cancer diagnosis.

Tijue Wang, Jakob Dremel, Sven Richter, Witold Polanski, Ortrud Uckermann, Ilker Eyüpoglu, Jürgen W Czarske, Robert Kuschmierz

Open access · goldAbstract read
In one paragraph

Article in Neurophotonics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 13 citations in OpenAlex.

  1. Current progress of digital twin construction using medical imaging.Journal of applied clinical medical physics · 2025
    Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Tijue WangTU Dresden, Laboratory of Measurement and Sensor System Technique, Dresden, Germany.
Jakob DremelTU Dresden, Laboratory of Measurement and Sensor System Technique, Dresden, Germany.ORCID https://orcid.org/0009-0000-0843-5779
Sven RichterTU Dresden, Else Kröner Fresenius Center for Digital Health, Germany.
Witold PolanskiTU Dresden, Else Kröner Fresenius Center for Digital Health, Germany.ORCID https://orcid.org/0000-0002-6603-5375
Ortrud UckermannTU Dresden, Else Kröner Fresenius Center for Digital Health, Germany.
Ilker EyüpogluTU Dresden, Else Kröner Fresenius Center for Digital Health, Germany.
Jürgen W CzarskeTU Dresden, Laboratory of Measurement and Sensor System Technique, Dresden, Germany.
Robert KuschmierzTU Dresden, Laboratory of Measurement and Sensor System Technique, Dresden, Germany.ORCID https://orcid.org/0000-0002-8321-7488
TU Dresden · DEUniversity Hospital Carl Gustav Carus · DEElse Kröner-Fresenius-Stiftung · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: Deep learning enables label-free all-optical biopsies and automated tissue classification. Endoscopic systems provide intraoperative diagnostics to deep tissue and speed up treatment without harmful tissue removal. However, conventional multi-core fiber (MCF) endoscopes suffer from low resolution and artifacts, which hinder tumor diagnostics. Aim: We introduce a method to enable unpixelated, high-resolution tumor imaging through a given MCF with a diameter of around 0.65 mm and arbitrary core arrangement and inhomogeneous transmissivity. Approach: Image reconstruction is based on deep learning and the digital twin concept of the single-reference-based simulation with inhomogeneous optical properties of MCF and transfer learning on a small experimental dataset of biological tissue. The reference provided physical information about the MCF during the training processes. Results: For the simulated data, hallucination caused by the MCF inhomogeneity was eliminated, and the averaged peak signal-to-noise ratio and structural similarity were increased from 11.2 dB and 0.20 to 23.4 dB and 0.74, respectively. By transfer learning, the metrics of independent test images experimentally acquired on glioblastoma tissue Conclusions: With the proposed approach, a single reference image was required in the pre-training stage and laborious acquisition of training data was bypassed. Validation on glioblastoma cryosections with transfer learning on only 50 image pairs showed the capability for high-resolution deep tissue retrieval and high clinical feasibility.

Indexed as

deep learningfiber bundle imagingtumor diagnosis

Identifiers

PMID38298866
PMCPMC10828892
OpenAlexW4391389175

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.