Evidence map›Paper›PMID 38298328›Full record

ArticleAdvances in radiation oncology2024

Clinical and Dosimetric Impact of 2D kV Motion Monitoring and Intervention in Liver Stereotactic Body Radiation Therapy.

Andrew P Santoso, Yevgeniy Vinogradskiy, Tyler P Robin, Karyn A Goodman, Tracey E Schefter, Moyed Miften, Bernard L Jones

Abstract read
In one paragraph

Article in Advances in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Andrew P SantosoDepartment of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado.
Yevgeniy VinogradskiyDepartment of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania.
Tyler P RobinDepartment of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado.
Karyn A GoodmanDepartment of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado.
Tracey E SchefterDepartment of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado.
Moyed MiftenDepartment of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado.
Bernard L JonesDepartment of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado.

Funding

Paul Calabresis Award in Clinical Oncology ResearchK12CA086913 · NCI · UNIVERSITY OF COLORADO DENVER · PI VIRGINIA F. BORGES, Jill E Slansky · 2000 to 2026
$17.8M
Coded-aperture Compton scatter imaging for real-time tumor motion tracking during ablative radiotherapyR21CA249647 · NCI · UNIVERSITY OF COLORADO DENVER · PI JONES, BERNARD L · 2021 to 2022
$313k
NCI NIH HHS K12 CA086913NCI NIH HHS R21 CA249647
6 · The paper itself

Abstract

Purpose: Positional errors resulting from motion are a principal challenge across all disease sites in radiation therapy. This is particularly pertinent when treating lesions in the liver with stereotactic body radiation therapy (SBRT). To achieve dose escalation and margin reduction for liver SBRT, kV real-time imaging interventions may serve as a potential solution. In this study, we report results of a retrospective cohort of liver patients treated using real-time 2D kV-image guidance SBRT with emphasis on the impact of (1) clinical workflow, (2) treatment accuracy, and (3) tumor dose. Methods and Materials: Data from 33 patients treated with 41 courses of liver SBRT were analyzed. During treatment, planar kV images orthogonal to the treatment beam were acquired to determine treatment interventions, namely treatment pauses (ie, adequacy of gating thresholds) or treatment shifts. Patients were shifted if internal markers were >3 mm, corresponding to the PTV margin used, from the expected reference condition. The frequency, duration, and nature of treatment interventions (ie, pause vs shift) were recorded, and the dosimetric impact associated with treatment shifts was estimated using a machine learning dosimetric model. Results: Of all fractions delivered, 39% required intervention, which took on average 1.9 ± 1.6 minutes and occurred more frequently in treatments lasting longer than 7 minutes. The median realignment shift was 5.7 mm in size, and the effect of these shifts on minimum tumor dose in simulated clinical scenarios ranged from 0% to 50% of prescription dose per fraction. Conclusion: Real-time kV-based imaging interventions for liver SBRT minimally affect clinical workflow and dosimetrically benefit patients. This potential solution for addressing positional errors from motion addresses concerns about target accuracy and may enable safe dose escalation and margin reduction in the context of liver SBRT.

Identifiers

PMID38298328
PMCPMC10828584

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.