ArticleAdvances in radiation oncology2024
Clinical Experience of Intrafractional Motion Monitoring of Patients Under Head and Neck Radiation Therapy Using ExacTrac Dynamic System.
Article in Advances in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Maskless head and neck radiotherapy using surface-guided radiation therapy: initial clinical feasibility of real-time setup, intrafraction monitoring, and automatic beam-hold.Journal of applied clinical medical physics · 2026Article
- Correction of image-guided radiotherapy and intrafraction motion using ExacTrac dynamic for head and neck cancer patients.Technical innovations & patient support in radiation oncology · 2026Article
- Accuracy of surface-guided radiotherapy-based positioning and surface tracking in breast radiotherapy using a thermo-optical camera system.Physical and engineering sciences in medicine · 2026Article
- Improvement in positional accuracy with integrated surface- and X-ray imaging for intracranial stereotactic radiosurgery patients.Physics and imaging in radiation oncology · 2026Article
- Integrating surface-guided radiation therapy and continuous positive airway pressure for breast cancer: Improving reproducibility and efficacy.Journal of applied clinical medical physics · 2025Article
- Use of surface tracking recordings to identify pitfalls during surface-guided radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025Article
- Optimizing Motion Management and Baseline Shifts in Magnetic Resonance-Guided Spine Stereotactic Body Radiation Therapy.Cancers · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The combination of surface-guided radiation therapy (SGRT) and image-guided radiation therapy (IGRT) can provide complementary information of patient positioning throughout treatments. The ExacTrac Dynamic (EXTD) system is a combined SGRT and IGRT system that can provide real-time motion detection via optical surface and thermal tracking during treatment delivery, with stereoscopic x-ray for positional verification. The purpose of this study was to examine the performance of EXTD for intrafractional motion monitoring using real clinical cases. Methods and Materials: Treatment log files exported from EXTD for 40 patients with 335 fractions were retrospectively analyzed. Frequency of beam-hold triggered during treatments were recorded, with the comparison of shifts detected by optical surface tracking (EXTD_Thml) and x-ray verification (EXTD_Xray). Results: Among the 335 fractions, automatic beam-holds were triggered 41 times, followed by x-ray positional verification with internal anatomy. The difference of shifts detected by EXTD_Thml and EXTD_Xray were less than 1 mm and 1° in translational and rotational directions, respectively. After x-ray verification, none of them required the application of positional correction. Conclusions: The availability of x-ray imaging with optical surface tracking in EXTD is essential to verify whether geometric shifts are required to correct patient position. Considering the ability of continuous monitoring of patient positions with optical surface tracking and internal imaging, EXTD is an effective tool for intrafractional motion monitoring during radiation therapy.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.