Evidence map›Paper›PMID 38292768›Full record

ArticleFrontiers in endocrinology2023

Comparison of EMG amplitudes recorded by ipsilateral and contralateral electrodes placement during using trans-thyroid cartilage recording method in thyroid surgery.

Feng-Yu Chiang, Yu-Chen Shih, Ching-Feng Lien, Chih-Chun Wang, Chien-Chung Wang, Tzer-Zen Hwang, Yaw-Chang Huang, Che-Wei Wu, Tai-Hung Yeh, Tzu-Yen Huang

Open access · goldAbstract readComparative Study
In one paragraph

Article in Frontiers in endocrinology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Comparison of EMG responses obtained from endotracheal tube and thyroid cartilage surface electrodes in thyroidectomies performed with intraoperative nerve monitoring.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Feng-Yu ChiangDepartment of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan.
Yu-Chen ShihDepartment of Otolaryngology, E-Da Cancer Hospital, Kaohsiung, Taiwan.
Ching-Feng LienDepartment of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan.
Chih-Chun WangDepartment of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan.
Chien-Chung WangDepartment of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan.
Tzer-Zen HwangDepartment of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan.
Yaw-Chang HuangDepartment of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan.
Che-Wei WuDepartment of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.
Tai-Hung YehDepartment of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan.
Tzu-Yen HuangDepartment of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.
E-Da Hospital · TWI-Shou University · TWKaohsiung Medical University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: The feasibility and reliability of trans-thyroid cartilage EMG recording method (TCERM) during intraoperative monitoring (IONM) of the recurrent laryngeal nerve (RLN) in thyroid surgery have been established. This study compared two different recording electrode placements on the ipsi-lateral and contra-lateral lamina of the thyroid cartilage (TC). Methods: Fifty consecutive patients undergoing total thyroidectomy with 100 RLNs at risk were enrolled. Two paired subdermal needle electrodes were inserted into the subperichondrium of the bilateral TC lamina to record electromyography (EMG) signals. The channel leads from the TC electrodes were connected to the patient interface with two different modes. In A-mode, the electrode leads were placed ipsi-laterally, and channel 1 monitored the left RLN and channel 2 monitored the right RLN respectively. In B-mode, the electrode leads were placed contra-laterally, and channels 1 and 2 simultaneously monitored the same side of the RLN. The amplitudes of four EMG signals (V Results: All EMG amplitudes of V Conclusion: During using TCERM in thyroid surgery, the recording electrodes should be placed contra-laterally on the TC lamina. This approach ensures high and stable EMG signals, which are important for high-quality IONM of the RLN.

Indexed as

Thyroid CartilageThyroid GlandAgedElectrodesHumansMaleReproducibility of ResultsThyroidectomyelectromyography (EMG)intraoperative neuromonitoring (IONM)recording methodrecurrent laryngeal nerve (RLN)thyroid surgery

Identifiers

PMID38292768
PMCPMC10826414
OpenAlexW4390910213

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked