Evidence map›Paper›PMID 38291748›Full record

ArticleNeurospine2024

The Efficacy of Cervical Pedicle Screw Is Enhanced When Used With 5.5-mm Rods for Metastatic Cervical Spinal Tumor Surgery.

Danbi Park, Sang Hyub Lee, Subum Lee, Jemin Park, Hyeon Gyu Yang, Chongman Kim, Jin Hoon Park

Open access · diamondAbstract read
In one paragraph

Article in Neurospine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.3field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Unilateral biportal endoscopic transpedicular intrabody cage augmentation for a metastatic spinal tumor with pathologic fracture: a technical note and case report.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Danbi ParkDepartment of Neurological Surgery, Asan Medical Center, Seoul, Korea.
Sang Hyub LeeDepartment of Neurosurgery, Spine Center, The Leon Wiltse Memorial Hospital, Suwon, Korea.
Subum LeeDepartment of Neurosurgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea.
Jemin ParkDepartment of Neurological Surgery, Asan Medical Center, Seoul, Korea.
Hyeon Gyu YangDepartment of Neurological Surgery, Asan Medical Center, Seoul, Korea.
Chongman KimDepartment of Industrial and Management Engineering, Myongji University, Seoul, Korea.
Jin Hoon ParkDepartment of Neurological Surgery, Asan Medical Center, Seoul, Korea.
Asan Medical Center · KRKorea University Medical Center · KRKorea University · KRMyongji University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe cervical spine presents challenges in treating metastatic cervical spinal tumors (MCSTs). Although the efficacy of cervical pedicle screw placement (CPS) has been well established, its use in combination with 5.5-mm rods for MCST has not been reported. This study aimed to evaluate the efficacy of CPS combined with 5.5-mm rods in treating MCST and compare it with that of CPS combined with traditional 3.5-mm rods.

methodsThis retrospective study analyzed 58 patients with MCST who underwent posterior cervical spinal fusion surgery by a single surgeon between March 2012 and December 2022. Data included demographics, surgical details, imaging results, numerical rating scale score for neck pain, Eastern Cooperative Oncology Group performance status, and Spine Oncology Study Group Outcomes Questionnaire responses.

resultsPreoperative Spinal Instability Neoplastic Scores were significantly higher in the 5.5-mm rod group. Greater kyphotic changes in the index vertebra were observed in the 3.5-mm rod group. Neck pain reduction was significantly better in the 5.5-mm rod group.

conclusionCPS with 5.5-mm rods provides superior biomechanical stability and effectively resists forward bending momentum in posterior MCST fusion surgery. These findings support the use of 5.5-mm rods to enhance surgical outcomes.

Indexed as

5.5-mm diameter rodCervical pedicle screwCervicothoracic junctionKyphosisMetastatic cervical spinal tumorPosterior cervical spinal fusion

Identifiers

PMID38291748
PMCPMC10992656
OpenAlexW4391315725

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.