Evidence map›Paper›PMID 38291259›Full record

ArticleHypertension research : official journal of the Japanese Society of Hypertension2024

Accuracy of 24 h ambulatory blood pressure recordings for diagnosing high 44 h blood pressure in hemodialysis: a diagnostic test study.

Marieta Theodorakopoulou, Areti Georgiou, Fotini Iatridi, Eleni Karkamani, Anastasia Stamatiou, Nikolaos Devrikis, Artemios Karagiannidis, Amalia Baroutidou, Pantelis Sarafidis

Abstract read
PubMed Publisher
In one paragraph

Article in Hypertension research : official journal of the Japanese Society of Hypertension, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Marieta TheodorakopoulouFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece. marietatheod@gmail.com.
Areti GeorgiouFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Fotini IatridiFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Eleni KarkamaniFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Anastasia StamatiouFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Nikolaos DevrikisFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Artemios KaragiannidisFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Amalia BaroutidouFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Pantelis SarafidisFirst Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hypertension is highly prevalent in hemodialysis patients. Ambulatory-BP-monitoring(ABPM) during the 44 h interdialytic interval is recommended for hypertension diagnosis and management in these subjects. This study assessed the diagnostic accuracy of fixed 24 h ABPM recordings with 44 h BP in hemodialysis patients. 242 Greek hemodialysis patients that underwent valid 48 h ABPM(Mobil-O-Graph NG device) were included in the analysis. We used 44 h BP as reference method and tested the accuracy of the following BP metrics: 1st 24 h without HD period (20 h-1st), 1st 24 h including HD period (24 h-1st) and 2nd 24 h(24 h-2nd). All studied metrics showed strong correlations with 44 h SBP/DBP (20 h-1st: r = 0.973/0.978, 24 h-1st: r = 0.964/0.972 and 24 h-2nd: r = 0.978/0.977, respectively). In Bland-Altman analysis, small between-method differences (-1.70, -1.19 and +1.45 mmHg) with good 95% limits-of agreement([-10.83 to 7.43], [-11.12 to 8.74] and [-6.33 to 9.23] mmHg, respectively) for 20 h-1st, 24 h-1st and 24 h-2nd SBP were observed. The sensitivity/specificity and κ-statistic for diagnosing 44 h SBP ≥ 130 mmHg were high for 20 h-1st SBP(87.2%/96.0%, κ-statistic = 0.817), 24 h-1st SBP(88.7%/96.0%, κ-statistic = 0.833) and 24 h-2nd SBP (95.0%/88.1%, κ-statistic = 0.837). Similar observations were made for DBP. In ROC-analyses, all studied BP metrics showed excellent performance with high Area-Under-the- Curve values (20 h-1st: 0.983/0.992; 24 h-1st: 0.984/0.987 and 24 h-2nd: 0.982/0.989 for SBP/DBP respectively). Fixed 24 h ABPM recordings during either the first or the second day of interdialytic interval have high accuracy and strong agreement with 44 h BP in hemodialysis patients. Thus, ABPM recordings of either the first or the second interdialytic day could be used for hypertension diagnosis and management in these subjects.

Indexed as

Blood Pressure Monitoring, AmbulatoryHypertensionBlood PressureDiagnostic Tests, RoutineHumansRenal DialysisAmbulatory blood pressure monitoringHemodialysisHypertensionInterdialytic

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.