ArticleMicrobiology spectrum2024
Development and evaluation of three automated media pooling and molecular diagnostic systems for the detection of SARS-CoV-2.
Article in Microbiology spectrum, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 5 citations in OpenAlex.
- Performance Evaluation of a Fully Automated Molecular Diagnostic System for Multiplex Detection of SARS-CoV-2, Influenza A/B Viruses, and Respiratory Syncytial Virus.Diagnostics (Basel, Switzerland) · 2025Article
- Three-year nationwide survey of microbiology laboratory equipment conditions in China's CDC: setting new benchmarks.Frontiers in public health · 2025Article
- Development of a simple and highly sensitive virion concentration method to detect SARS-CoV-2 in saliva.Heliyon · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
Pooled testing combined with molecular diagnostics for the detection of SARS-CoV-2 is a promising method that can increase testing capacities and save costs. However, pooled testing is also associated with the risks of decreased test sensitivity and specificity. To perform reliable pooled testing, we developed and validated three automated media pooling and molecular diagnostic systems. These pooling systems (geneLEAD-PS, Panther-PS, and Biomek-PS) comprised existing automated molecular detection platforms, corresponding automated media pooling devices, and laboratory information management systems. Analytical sensitivity analysis and mock sample evaluation were performed, and the obtained data were used to determine the sizes of the pool for the validation study. In the validation study, a total of 2,448, 3,228, and 6,420 upper respiratory samples were used for geneLEAD-PS, Panther-PS, and Biomek-PS, respectively, and the diagnostic performances were compared with the reference RT‒PCR assay. A pool size of 6 for geneLEAD-PS and a pool size of 4 for Panther-PS and Biomek-PS were selected for the validation studies. All three systems showed high positive percent agreement values of ≥90.5% and negative percent agreement values of ≥99.8% for any specimen type. Pooled testing resulted in a 65%-71% reduction in cost per sample. The testing capacities of geneLEAD-PS, Panther-PS, and Biomek-PS were 144 samples in 3 hours, 384 samples in 5.5 hours, and 376 samples in 4 hours, respectively. The developed pooling systems showed robust diagnostic performances and will increase the testing capacities of molecular diagnostic tests while saving costs and may contribute to infection control of COVID-19.IMPORTANCEDuring the COVID-19 pandemic, there have been surges in demand for accurate molecular diagnostic testing and laboratory supply shortages. Pooled testing combined with highly sensitive molecular testing, which entails mixing multiple samples as a single sample, is a promising approach to increase testing capacities while reducing the use of consumables. However, pooled testing is associated with risks that compromise diagnostic performance, such as false negatives due to dilution of positive samples or false positives due to cross-contamination. To perform reliable pooled testing, three different pooling systems (an automated pooling device, an automated molecular detection platform, and a laboratory information management system) were developed to accurately interpret pooled testing results. These three systems were validated using multiple clinical samples and showed high concordance with individual testing. The developed pooling systems will contribute to increasing reliable molecular testing capacities while using fewer consumables and saving costs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.