Evidence map›Paper›PMID 38289518›Full record

ArticleEJNMMI research2024

ParaPET: non-invasive deep learning method for direct parametric brain PET reconstruction using histoimages.

Rajat Vashistha, Hamed Moradi, Amanda Hammond, Kieran O'Brien, Axel Rominger, Hasan Sari, Kuangyu Shi, Viktor Vegh, David Reutens

Open access · goldAbstract read
In one paragraph

Article in EJNMMI research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
5.7field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Applications of artificial intelligence in nuclear medicine.Zeitschrift fur medizinische Physik · 2026
    Review
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Rajat VashisthaCentre for Advanced Imaging, University of Queensland, Brisbane, Australia.
Hamed MoradiCentre for Advanced Imaging, University of Queensland, Brisbane, Australia.
Amanda HammondSiemens Healthcare Pty Ltd, Melbourne, Australia.
Kieran O'BrienSiemens Healthcare Pty Ltd, Melbourne, Australia.
Axel RomingerDepartment of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, 3010, Bern, Switzerland.
Hasan SariAdvanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland.
Kuangyu ShiDepartment of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, 3010, Bern, Switzerland.
Viktor VeghCentre for Advanced Imaging, University of Queensland, Brisbane, Australia. viktor.vegh@cai.uq.edu.au.ORCID http://orcid.org/0000-0002-4310-1421
David ReutensCentre for Advanced Imaging, University of Queensland, Brisbane, Australia.
The University of Queensland · AUUniversity of Bern · CHSiemens (Australia) · AUQueensland University of Technology · AU

Funding

Australian Research Council Training Centre for Innovation in Biomedical Imaging Technology IC170100035
6 · The paper itself

Abstract

backgroundThe indirect method for generating parametric images in positron emission tomography (PET) involves the acquisition and reconstruction of dynamic images and temporal modelling of tissue activity given a measured arterial input function. This approach is not robust, as noise in each dynamic image leads to a degradation in parameter estimation. Direct methods incorporate into the image reconstruction step both the kinetic and noise models, leading to improved parametric images. These methods require extensive computational time and large computing resources. Machine learning methods have demonstrated significant potential in overcoming these challenges. But they are limited by the requirement of a paired training dataset. A further challenge within the existing framework is the use of state-of-the-art arterial input function estimation via temporal arterial blood sampling, which is an invasive procedure, or an additional magnetic resonance imaging (MRI) scan for selecting a region where arterial blood signal can be measured from the PET image. We propose a novel machine learning approach for reconstructing high-quality parametric brain images from histoimages produced from time-of-flight PET data without requiring invasive arterial sampling, an MRI scan, or paired training data from standard field-of-view scanners.

resultThe proposed is tested on a simulated phantom and five oncological subjects undergoing an 18F-FDG-PET scan of the brain using Siemens Biograph Vision Quadra. Kinetic parameters set in the brain phantom correlated strongly with the estimated parameters (K

conclusionWe proposed a direct non-invasive DL-based reconstruction method and produced high-quality parametric maps of the brain. The use of histoimages holds promising potential for enhancing the estimation of parametric images, an area that has not been extensively explored thus far. The proposed method can be applied to subject-specific dynamic PET data alone.

Indexed as

Deep learningDirect parametric image reconstructionHistoimagesPositron emission tomography

Identifiers

PMID38289518
PMCPMC11374951
OpenAlexW4391361487

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked