Evidence map›Paper›PMID 38286844›Full record

ArticleMikrochimica acta2024

Point-of-care impedimetric aptasensor to detect the luteinizing hormone.

Pankaj Kumar, Arumugam Anitha, Ankita Das, Govindarajan Deepalakshmi, Pankaj Suman

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Pankaj KumarAnimal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India.
Arumugam AnithaAnimal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India.
Ankita DasAnimal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India.
Govindarajan DeepalakshmiAnimal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India.
Pankaj SumanAnimal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India. pankajsuman@niab.org.in.
National Institute of Animal Biotechnology · INManipal Academy of Higher Education · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Luteinizing hormone (LH) is a useful biomarker for identifying ovulation events in the cows to predict the time of ovulation to achieve a high success rate of conception following artificial insemination. Although antibody-based radioimmunoassay and enzyme-linked immunosorbent assay are being used for LH measurement, these techniques are expensive, time-consuming, and require expertise and sophisticated laboratory facilities. So, there is a need for a field-applicable, affordable, easy-to-use method for LH detection. For developing such a specific, quantitative, and inexpensive system, an aptamer-based smartphone-enabled aptasensor has been investigated. The aptamer was used instead of the antibody as a biorecognition element due to its comparative stability at ambient temperature, ease of synthesis, and cost-effectiveness. Electrochemical impedance spectroscopy has been used to obtain label-free detection of LH within 20 min in ~ 20 μL sample volume. The screen-printed gold electrode is compatible with a smartphone-enabled miniaturized device (Sensit Smart; Palmsens BV, The Netherlands) and was fabricated with the aptamer to detect LH in biological fluids (limit of detection 0.80 and 0.61 ng/mL in buffer and undiluted/unprocessed serum, respectively, with the dynamic range of detection of 0.01 to 50 ng/mL). All the data were obtained in the 10 kHz to 0.10 Hz frequency range at a bias potential of 0.30 V with an alternating potential of 10 mV. The clinical relevance of the sensor was evaluated in 10 serum samples collected from dairy animals which established a high correlation with standard LH-ELISA (κ > 0.87). The aptasensor can be stored at room temperature for 30 days without any significant loss in electrochemical sensing ability.

Indexed as

Aptamers, NucleotideBiosensing TechniquesAnimalsCattleElectrochemical TechniquesLuteinizing HormonePoint-of-Care SystemsAptamers, NucleotideLuteinizing HormoneAptasensorElectrochemical impedance spectroscopyLuteinizing hormoneOvulation predictionScreen-printed gold electrode

Identifiers

PMID38286844
OpenAlexW4391328271

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.