Evidence map›Paper›PMID 38285623›Full record

ArticleMedical physics2024

Correcting CT misregistration in data-driven gated (DDG) PET with PET self-gating and deformable image registration.

Peng Sun, M Allan Thomas, Dershan Luo, Tinsu Pan

Abstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Peng SunDepartment of Imaging Physics, UT MD Anderson Cancer Center, Houston, Texas, USA.
M Allan ThomasMallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, Missouri, USA.
Dershan LuoDepartment of Radiation Physics, UT MD Anderson Cancer Center, Houston, Texas, USA.
Tinsu PanDepartment of Imaging Physics, UT MD Anderson Cancer Center, Houston, Texas, USA.

Funding

Risk prediction and longitudinal assessment of cardiotoxicity and functional capacity trajectory in NSCLC patientsR01HL157273 · NHLBI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI LIAO, ZHONGXING · 2021 to 2025
$3.8M
NHLBI NIH HHS R01 HL157273NIH HHS R01-HL157273-01
6 · The paper itself

Abstract

backgroundMisregistration between CT and PET data can result in mis-localization and inaccurate quantification of functional uptake in whole body PET/CT imaging. This problem is exacerbated when an abnormal inspiration occurs during the free-breathing helical CT (FB CT) used for attenuation correction of PET data. In data-driven gated (DDG) PET, the data selected for reconstruction is typically derived from the end-expiration (EE) phase of the breathing cycle, making this potential issue worse. PURPOSE: The objective of this study is to develop a deformable image registration (DIR)-based respiratory motion model to improve the registration and quantification between misregistered FB CT and PET.

methodsTwenty-two whole-body

resultsBetween DDG PET/FB CT and DDG PET/DIR CT, a significant increase in ∆%SUV was observed (p < 0.01), with median values elevating from 26.7% to 42.4%. This new method was most effective for lesions ≤3 cm proximal to the diaphragm (p < 0.001) but showed decreasing efficacy as the distance increased. When FB CT was severely misregistered with DDG PET (>3 cm), DDG PET/DIR CT outperformed DDG PET/FB CT alone (p < 0.05). Even when patients showed varied breathing patterns during the PET/CT scan, DDG PET/DIR CT still surpassed the efficiency of DDG PET/FB CT (p < 0.01). Though DDG PET/DIR CT couldn't match the performance of the DDG PET/CT ground truth (42.4% vs. 53.6%, p < 0.01), it reached 84% of its quantification, demonstrating good agreement and a strong overall correlation (regression coefficient of 0.94, p < 0.0001). In some cases, anatomical distortion and blurring, and misregistration error were observed in DIR CT, rendering it still unable to correct inaccurate localization near the boundaries of two organs.

conclusionsBased on the motion model derived from gated PET data, DIR CT can significantly improve the quantification and localization of DDG PET. This approach can achieve a performance level of about 84% of the ground truth established by DDG PET/CT. These results show that self-gated PET and DIR CT may offer an alternative clinical solution to DDG PET and FB CT for quantification without the need for additional cine-CT imaging. DIR CT was at times inferior to DDG CT due to some distortion and blurring of anatomy and misregistration error.

Indexed as

Positron Emission Tomography Computed TomographyRespirationExhalationHumansPositron-Emission TomographyTomography, X-Ray Computeddeformable image registrationmotion managementPET/CT

Identifiers

PMID38285623
PMCPMC10939831

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.