Evidence map›Paper›PMID 38285460›Full record

ArticleTranslational vision science & technology2024

Biometry-Based Technique for Determining the Anterior Scleral Thickness: Validation Using Optical Coherence Tomography Landmarks.

Satish Kumar Gupta, Rohit Dhakal, Pavan Kumar Verkicharla

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 citations in OpenAlex.

  1. Urban-Rural and School-Type Disparities in the Prevalence of Myopia and High Myopia in South India.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
    Article
  2. Article
  3. Analysis of In Vivo Sclera Impact on the Biomechanics of Myopic Eyes.Translational vision science & technology · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Satish Kumar GuptaMyopia Research Lab, Prof. Brien Holden Eye Research Centre, Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.
Rohit DhakalMyopia Research Lab, Prof. Brien Holden Eye Research Centre, Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.
Pavan Kumar VerkicharlaMyopia Research Lab, Prof. Brien Holden Eye Research Centre, Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.
L V Prasad Eye Institute · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Considering the potential role of anterior scleral thickness (AST) in myopia and the ubiquitous use of optical biometers, we applied and validated a biometry-based technique for estimating AST using optical coherence tomography (OCT) landmarks. Methods: The AST was determined across four meridians in 62 participants (aged 20-37 years) with a swept-source OCT and a noncontact optical biometer at a mean ± SD distance of 3.13 ± 0.88 mm from the limbus. The biometer's graticule was focused and aligned with the anterior scleral reflex, which led to the generation of four prominent A-scan peaks: P1 (anterior bulbar conjunctiva), P2 (anterior episclera), P3 (anterior margin of anterior sclera), and P4 (posterior margin of anterior sclera), which were analyzed and compared with the corresponding OCT landmarks to determine tissue thickness. Results: The AST measurements between biometer and OCT correlated for all meridians (r ≥ 0.70, overall r = 0.82; coefficient of variation [CV], 9%-12%; P < 0.01). The mean difference ± SD between two instruments for overall AST measures was 3 ± 2.8 µm (range, -18 to +16 µm; lower limits of agreement, -89 to +83 µm; P = 0.23) across all meridians. The mean ± SE AST with both instruments was found to be thickest at the inferior (562 ± 7 µm and 578 ± 7 µm) and thinnest at the superior (451 ± 7 µm and 433 ± 6 µm) meridian. The biometer demonstrated good intrasession (CV, 8.4%-9.6%) and intersession (CV, 7.9%-13.3%) repeatability for AST measurements across all meridians. Conclusions: The noncontact optical biometer, which is typically used to determine axial length, is capable of accurately estimating AST based on OCT landmarks. Translational Relevance: The high-resolution optical biometers can demonstrate wider application in the field of myopia research and practice to determine AST.

Indexed as

MyopiaScleraBiometryConjunctivaHumansTomography, Optical Coherence

Identifiers

PMID38285460
PMCPMC10829803
OpenAlexW4391324498

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.