Evidence map›Paper›PMID 38285267›Full record

SynthesisJournal of robotic surgery2024

Intraoperative complications of robotic-assisted extended totally extraperitoneal (eTEP) ventral hernia retromuscular repairs with mesh: a systematic literature review and narrative synthesis.

Edward Young, Alex Karatassas, Anita Jacombs, Guy John Maddern

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Journal of robotic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.3field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Edward YoungThe University of Adelaide Discipline of Surgery, The Queen Elizabeth Hospital, 28 Woodville Road, Woodville South, South Australia, 5011, Australia. e.young@adelaide.edu.au.ORCID http://orcid.org/0000-0002-5262-5200
Alex KaratassasThe University of Adelaide Discipline of Surgery, The Queen Elizabeth Hospital, 28 Woodville Road, Woodville South, South Australia, 5011, Australia.
Anita JacombsFaculty of Medicine and Health Nepean Clinical School, The University of Sydney, Sydney, New South Wales, Australia.
Guy John MaddernThe University of Adelaide Discipline of Surgery, The Queen Elizabeth Hospital, 28 Woodville Road, Woodville South, South Australia, 5011, Australia.
Queen Elizabeth Hospital · AUThe University of Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Minimally invasive extended totally extraperitoneal (eTEP) technique is revolutionising ventral hernia repairs. Robotic-assisted eTEP has been gaining popularity due to better visual clarity and greater dexterity provided by the robotic systems, compared to laparoscopy. Despite growing number of papers being published each year, so far, no study has explored intraoperative complications in robotic-assisted eTEP. The aim was to perform a systematic literature review on the incidence of intraoperative complications in robotic-assisted eTEP ventral hernia repairs. The study protocol was preregistered with PROSPERO, registration number CRD42023450072. Twelve categories of intraoperative complications were defined by the authors. A search of PubMed and Embase was conducted on 16/08/2023, for articles pertaining to robotic-assisted eTEP operations in ventral hernias in adults. Articles were critically appraised and data were extracted using predefined extraction templates. No data were suitable for statistical analysis and a narrative synthesis was performed instead. Ten studies fulfilled the inclusion criteria, of which four studies reported intraoperative complications. Of the 12 categories of intraoperative complications, only 5 were reported. Three studies encountered adherent bowel inside the hernia sac. One reported linea alba injury with subsequent anterior layer dehiscence. There was one case of unrecognised intraoperative retromuscular bleeding and one case of insufflation injury with subcutaneous emphysema. There is a paucity of literature on the incidence of intraoperative complications in robotic-assisted eTEP ventral hernia repairs. Available studies suggest complication rates are low. More robust studies using prospective data from hernia registries are required before further conclusions can be drawn.

Indexed as

Hernia, VentralRobotic Surgical ProceduresAdultHerniorrhaphyHumansIntraoperative ComplicationsProspective StudiesSurgical MesheTEPGeneral surgeryIntraoperative complicationsSystematic reviewVentral hernia

Identifiers

PMID38285267
OpenAlexW4391314171

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.