Evidence map›Paper›PMID 38285228›Full record

ArticleAnalytical and bioanalytical chemistry2024

Comparative study of the vibrating capillary nebulizer (VCN) and commercially available interfaces for on-line coupling of capillary electrophoresis with ICP-MS.

Tristen L Taylor, Dariya Tukhmetova, Thi Phuong Thanh Duong, Anna-Maria Böwe, Björn Meermann, Alexander Gundlach-Graham

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 3 countries.

Tristen L Taylor *Department of Chemistry, Iowa State University, Ames, IA, USA.
Dariya Tukhmetova *Division 1.1 - Inorganic Trace Analysis, Federal Institute for Materials Research and Testing (BAM), Berlin, Germany.
Thi Phuong Thanh DuongDivision 1.1 - Inorganic Trace Analysis, Federal Institute for Materials Research and Testing (BAM), Berlin, Germany.
Anna-Maria BöweDivision 4.3 - Contaminant Transport and Environmental Technologies, Federal Institute for Materials Research and Testing (BAM), Berlin, Germany.
Björn MeermannDivision 1.1 - Inorganic Trace Analysis, Federal Institute for Materials Research and Testing (BAM), Berlin, Germany. bjoern.meermann@bam.de.
Alexander Gundlach-GrahamDepartment of Chemistry, Iowa State University, Ames, IA, USA. alexgg@iastate.edu.
Federal Institute For Materials Research and Testing · DEIowa State University · USUniversity of Tartu · EE

Funding

Deutsche Forschungsgemeinschaft ME 3685/5-1Deutsche Forschungsgemeinschaft project number: 440953647
6 · The paper itself

Abstract

Capillary electrophoresis (CE) is a powerful and sensitive tool for speciation analysis when combined with inductively coupled plasma mass spectrometry (ICP-MS); however, the performance of this technique can be limited by the nature of pneumatic nebulizers. This study compares two commercially available pneumatic nebulizers to a newly introduced vibrating capillary nebulizer (VCN) for on-line coupling of CE with ICP-MS. The VCN is a low-cost, non-pneumatic nebulizer that is based on the design of capillary vibrating sharp-edge spray ionization. As a piezoelectrically driven nebulization source, the VCN creates an aerosol independent of gas flows and does not produce a low-pressure region at the nebulizer orifice. To compare the systems, we performed replicate analyses of sulfate in river water with each nebulizer and the same CE and ICP-MS instruments and determined the figures of merit of each setup. With the CE-VCN-ICP-MS setup, we achieved around 2-4 times lower sensitivity compared to the commercial setups. However, the VCN-based setup provided lower noise levels and better linear correlation from the analysis of calibration standards, which resulted in indistinguishable LOD and LOQ values from the in-house-built VCN-based and commercial setups for CE-ICP-MS analysis. The VCN is found to have the highest baseline stability with a standard deviation of 3500 cts s

Indexed as

Capillary electrophoresisElectrophoresisICP-MSMass spectrometryNebulizerSeparations/instrumentationSpeciation

Identifiers

PMID38285228
OpenAlexW4391311976

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.