Evidence map›Paper›PMID 38282721›Full record

ArticleNeurophotonics2024

Comparing the performance potential of speckle contrast optical spectroscopy and diffuse correlation spectroscopy for cerebral blood flow monitoring using Monte Carlo simulations in realistic head geometries.

Mitchell B Robinson, Tom Y Cheng, Marco Renna, Melissa M Wu, Byungchan Kim, Xiaojun Cheng, David A Boas, Maria Angela Franceschini, Stefan A Carp

Abstract read
In one paragraph

Article in Neurophotonics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Pathlength-selective, interferometric diffuse correlation spectroscopy.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society
    Article
  14. Validation of the Linearity in Image Reconstruction Methods for Speckle Contrast Optical Tomography.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society
    Article
  15. Comprehensive Optimization of Interferometric Diffusing Wave Spectroscopy (iDWS).IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mitchell B RobinsonMassachusetts General Hospital, Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Boston, Massachusetts, United States.ORCID https://orcid.org/0000-0001-5810-0459
Tom Y ChengMassachusetts General Hospital, Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Boston, Massachusetts, United States.ORCID https://orcid.org/0000-0003-3220-7471
Marco RennaMassachusetts General Hospital, Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Boston, Massachusetts, United States.
Melissa M WuDuke University, Department of Biomedical Engineering, Durham, North Carolina, United States.ORCID https://orcid.org/0000-0001-6083-2464
Byungchan KimBoston University, Neurophotonics Center, Department of Biomedical Engineering, Boston, Massachusetts, United States.ORCID https://orcid.org/0000-0001-5144-7644
Xiaojun ChengBoston University, Neurophotonics Center, Department of Biomedical Engineering, Boston, Massachusetts, United States.
David A BoasBoston University, Neurophotonics Center, Department of Biomedical Engineering, Boston, Massachusetts, United States.ORCID https://orcid.org/0000-0002-6709-7711
Maria Angela FranceschiniMassachusetts General Hospital, Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Boston, Massachusetts, United States.ORCID https://orcid.org/0000-0001-6758-423X
Stefan A CarpMassachusetts General Hospital, Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Boston, Massachusetts, United States.ORCID https://orcid.org/0000-0003-4617-3233

Funding

Time-Gated Diffuse Correlation Spectroscopy for functional imaging of the human brainU01EB028660 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI FRANCESCHINI, MARIA ANGELA · 2019 to 2023
$6.4M
Non-invasive monitoring of brain health during cardio-pulmonary bypassR01NS100750 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI CARP, STEFAN ALEXANDRU · 2018 to 2022
$2.9M
A transformative method for functional brain imaging with Speckle Contrast Optical SpectroscopyUG3EB034710 · NIBIB · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI BOAS, DAVID A, CHENG, XIAOJUN · 2023 to 2025
$1.1M
Highly parallel long wavelength heterodyne diffuse correlation spectroscopy for brain functional imagingR01EB033202 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI CARP, STEFAN ALEXANDRU · 2022 to 2022
$858k
NIBIB NIH HHS R01 EB033202NIBIB NIH HHS U01 EB028660NIBIB NIH HHS UG3 EB034710NINDS NIH HHS R01 NS100750
6 · The paper itself

Abstract

Significance: The non-invasive measurement of cerebral blood flow based on diffuse optical techniques has seen increased interest as a research tool for cerebral perfusion monitoring in critical care and functional brain imaging. Diffuse correlation spectroscopy (DCS) and speckle contrast optical spectroscopy (SCOS) are two such techniques that measure complementary aspects of the fluctuating intensity signal, with DCS quantifying the temporal fluctuations of the signal and SCOS quantifying the spatial blurring of a speckle pattern. With the increasing interest in the use of these techniques, a thorough comparison would inform new adopters of the benefits of each technique. Aim: We systematically evaluate the performance of DCS and SCOS for the measurement of cerebral blood flow. Approach: Monte Carlo simulations of dynamic light scattering in an MRI-derived head model were performed. For both DCS and SCOS, estimates of sensitivity to cerebral blood flow changes, coefficient of variation of the measured blood flow, and the contrast-to-noise ratio of the measurement to the cerebral perfusion signal were calculated. By varying complementary aspects of data collection between the two methods, we investigated the performance benefits of different measurement strategies, including altering the number of modes per optical detector, the integration time/fitting time of the speckle measurement, and the laser source delivery strategy. Results: Through comparison across these metrics with simulated detectors having realistic noise properties, we determine several guiding principles for the optimization of these techniques and report the performance comparison between the two over a range of measurement properties and tissue geometries. We find that SCOS outperforms DCS in terms of contrast-to-noise ratio for the cerebral blood flow signal in the ideal case simulated here but note that SCOS requires careful experimental calibrations to ensure accurate measurements of cerebral blood flow. Conclusion: We provide design principles by which to evaluate the development of DCS and SCOS systems for their use in the measurement of cerebral blood flow.

Indexed as

cerebral blood flowdiffuse correlation spectroscopyMonte Carlo simulationspeckle contrast optical spectroscopy

Identifiers

PMID38282721
PMCPMC10821780

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.