Evidence map›Paper›PMID 38280939›Full record

ArticleScientific reports2024

New micro-hole zone catheter reduces residual urine and mucosal microtrauma in a lower urinary tract model.

Brit Schrøder, Fabio Tentor, Teodora Miclăuş, Kristian Stærk, Thomas Emil Andersen, Michele Spinelli, Claudia Rendeli, Giulio Del Popolo, Per Bagi, Lene Feldskov Nielsen

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
6.4field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Draining Urinary Sediments Through Conventional Eyelet Catheters and New Intermittent Micro-Hole Zone Catheters.Journal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society
    Trial
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 6 institutions in 2 countries.

Brit SchrøderColoplast A/S, Holtedam 1, 3050, Humlebaek, Denmark.
Fabio TentorColoplast A/S, Holtedam 1, 3050, Humlebaek, Denmark.
Teodora MiclăuşAML Christensen, Nivaa Strandpark 21, Nivaa, Denmark.
Kristian StærkDepartment of Clinical Microbiology, Odense University Hospital, Odense, Denmark.
Thomas Emil AndersenDepartment of Clinical Microbiology, Odense University Hospital, Odense, Denmark.
Michele SpinelliSpinal Unit, Niguarda Hospital, Milan, Italy.
Claudia RendeliDepartment of Pediatrics, Università Cattolica del Sacro Cuore, Rome, Italy.
Giulio Del PopoloNeuro-Urology Department, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy.
Per BagiDepartment of Urology, Rigshospitalet, Blegdamsvej 9, 2100, Copenhagen, Denmark.
Lene Feldskov NielsenColoplast A/S, Holtedam 1, 3050, Humlebaek, Denmark. dklfn@coloplast.com.
Coloplast (Denmark) · DKOdense University Hospital · DKAzienda Ospedaliero-Universitaria Careggi · ITAzienda Socio Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda · ITRigshospitalet · DKUniversità Cattolica del Sacro Cuore · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Urinary tract infections (UTIs) are the main complication associated with clean intermittent catheterization (CIC) and are facilitated by post-void residual urine and trauma to the mucosa during voiding. The risk of UTI may be diminished by reducing the residual volumes and preventing microtrauma caused by mucosal suction through the eyelets of conventional eyelet catheters (CEC). A new micro-hole zone catheter (MHZC) was developed and tested in an ex vivo porcine lower urinary tract model and in vivo, in pigs, against a CEC. It was shown that, irrespective of the micro-hole diameter, the new catheter ensured increased flowrates and significantly lower residual volumes at the first flow-stop. Furthermore, with a micro-hole diameter of 0.4 mm, mucosal suction was virtually eliminated, regardless of the insertion depth or simulated intra-abdominal pressure mimicking sitting or standing humans. Pressure profile experiments and endoscopy studies indicated that the bladder gradually folds against the drainage tip of the new catheter, without blocking the flow, and, unlike with the CEC, sharp pressure variations and flow-stops did not occur during voiding. The MHZC outperformed the CEC in all tested scenarios and decreased residual volumes, thus potentially decreasing the risk of UTIs.

Indexed as

Intermittent Urethral CatheterizationUrinary RetentionUrinary Tract InfectionsAnimalsCathetersHumansSwineUrinary Bladder

Identifiers

PMID38280939
PMCPMC10821950
OpenAlexW4391281146

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.