ArticleScientific reports2024
Ventilation control of road tunnels towards disturbance suppression.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Experimental study on variable frequency control and air leakage control of multi-fan combination in subway tunnels.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In recent years, research on ventilating tunnels has become increasingly important. However, the impact of external disturbances on ventilating systems has been largely ignored. To address this issue of frequent airflow fluctuations caused by external perturbations, which cannot be fully compensated using conventional control methods, this study proposes a perturbation-compensated ventilation control approach. A disturbance compensator is developed by incorporating the tunnel's airflow velocity and the number of jet fan start-stop events as input parameters. By compensating for external disturbances, the disturbance to the system is reduced. The Simulink model of the tunnel controller was used for simulation experiments. The compensator demonstrated good tracking results in comparison experiments with different disturbances. The ventilation approach based on disturbance compensator is capable of regulating the fluctuation of CO concentration within a justifiable range compared to using PID control and ADRC. This not only improves the stability of the entire control system but also significantly prolongs the service life of the jet fan by reducing the frequency of start-stop cycles.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.