ReviewJournal of applied clinical medical physics2024
Intraoperative radiation therapy with 50 kV x-rays: A multi-institutional review.
Review in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Monte Carlo assessment of a treatment planning system for intraoperative radiotherapy in the presence of tissue heterogeneities.Medical physics · 2026Article
- A novel methodology using direct patient contact and UK national registries to collect long-term data from randomised trials: TARGIT-X - an extended follow-up study of the TARGIT-A trial of targeted intraoperative radiotherapy for breast cancer.Health technology assessment (Winchester, England) · 2026Article
- Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator.Radiation oncology (London, England) · 2026Article
- Efficient X-Ray Source Probe Adjustment of the Intrabeam Intraoperative Radiotherapy System.Cureus · 2026Article
- Evaluation of the TG-43 formalism for intraoperative radiotherapy dosimetry in glioblastoma treatment.Medical physics · 2025Article
- Evaluating the efficacy of low-kV X-ray intraoperative radiotherapy in the treatment of locally advanced rectal cancer: a retrospective cohort study.Quantitative imaging in medicine and surgery · 2024Article
- Combined therapy of intraoperative radiotherapy and surgery for rectal cancer with inguinal lymph node metastasis: a case description.Quantitative imaging in medicine and surgery · 2024Article
- Intraoperative radiation therapy with 50 kV x-rays: A multi-institutional review.Journal of applied clinical medical physics · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This report covers clinical implementation of a low kV intraoperative radiation therapy (IORT) program with the INTRABEAM® System (Carl Zeiss Meditec AG, Jena, Germany). Based on collective user experience from eight institutions, we discuss best methods of INTRABEAM quality assurance (QA) tests, commissioning measurements, clinical workflow, treatment planning, and potential avenues for research. The guide provides pertinent background information and clinical justification for IORT. It describes the INTRABEAM system and commissioning measurements along with a TG100 risk management analysis to ensure safety and accuracy of the IORT program. Following safety checks, dosimetry measurements are performed for verification of field flatness and symmetry, x-ray output, and depth dose. Also discussed are dose linearity checks, beam isotropy, ion chamber measurements, calibration protocols, and in-vivo dosimetry with optically stimulated luminescence dosimeters OSLDs, and radiochromic film. Emphasis is placed on the importance of routine QA procedures (daily, monthly, and annual) performed at regular intervals for a successful IORT program. For safe and accurate dose delivery, tests of important components of IORT clinical workflow are emphasized, such as, dose prescription, pre-treatment QA, treatment setup, safety checks, radiation surveys, and independent checks of delivered dose. Challenges associated with in-vivo dose measurements are discussed, along with special treatment procedures and shielding requirements. The importance of treatment planning in IORT is reviewed with reference to a Monte Carlo-based commercial treatment planning system highlighting its main features and limitations. The report concludes with suggested topics for research including CT-based image-guided treatment planning and improved prescription dose accuracy. We hope that this multi-institutional report will serve as a guidance document on the clinical implementation and use of INTRABEAM IORT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.