Inter- and intra-rater reproducibility of quantitative T1 measurement using semiautomatic region of interest placement in myometrium.

Sadahiro Nakagawa, Takahiro Uno, Shunta Ishitoya, Eriko Takabayashi, Akiko Oya, Wakako Kubota, Atsutaka Okizaki

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sadahiro NakagawaDivision of Radiology, Asahikawa Medical University Hospital, Asahikawa, Japan.ORCID 0000-0003-2078-4888
Takahiro UnoDivision of Radiology, Asahikawa Medical University Hospital, Asahikawa, Japan.
Shunta IshitoyaDepartment of Radiology, Asahikawa Medical University, Asahikawa, Japan.
Eriko TakabayashiDepartment of Radiology, Asahikawa Medical University, Asahikawa, Japan.
Akiko OyaDepartment of Radiology, Asahikawa Medical University, Asahikawa, Japan.
Wakako KubotaDepartment of Radiology, Asahikawa Medical University, Asahikawa, Japan.
Atsutaka OkizakiDepartment of Radiology, Asahikawa Medical University, Asahikawa, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to investigate the inter- and intraobserver reproducibility of quantitative T1 (qT1) measurements using manual and semiautomatic region of interest (ROI) placements. We hypothesized the usefulness of the semiautomatic method, which utilizes a three-dimensional (3D) anatomical relationship between the myometrium and other tissues, for minimizing ROI placement variation, thereby improving qT1 reproducibility compared to the manual approach. The semiautomatic approach, which considered anatomical relationships, was expected to enhance reproducibility by reducing ROI placement variabilities. MATERIALS AND

methodsThis study recruited 23 healthy female volunteers. Data with variable flip angle (VFA) and inversion recovery were acquired using 3D-spoiled gradient echo and spin echo sequences, respectively. T1 maps were generated with VFA. Manual and semiautomatic ROI placements were independently conducted. Mean qT1 values were calculated from the T1 maps using the corresponding pixel values of the myometrial ROI. Inter- and intraobserver reproducibility of qT1 values was investigated. The inter- and intraobserver reproducibility of qT1 values was evaluated by calculating the coefficient of variation (CoV). Further, reproducibility was evaluated with inter- and intraobserver errors and intraclass correlation coefficients (ICCs). Bland-Altman analysis was utilized to compare the results, estimate bias, and determine the limits of agreement.

resultsThe mean inter- and intraobserver CoV of the qT1 values for semiautomatic ROI placement was significantly lower than those for manual ROI placement (p < 0.05 and p < 0.01, respectively). ICCs for semiautomatic ROI placement were greater than those for manual ROI placement. Further, the mean inter- and intraobserver errors for semiautomatic ROI placement were significantly lower than those for manual ROI placement (p < 0.05 and p < 0.01, respectively).

conclusionSemiautomatic ROI placement demonstrated high reproducibility of qT1 measurements compared with manual methods. Semiautomatic ROI placement may be useful for evaluating uterine qT1 with high reproducibility.

Indexed as

MyometriumFemaleHumansObserver VariationReproducibility of Results