Effect of Disinfection Method and Testing Methodology on the Performance of a Breath-Enhanced Jet Nebulizer.
Article in Pharmaceutics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
National guidelines for cystic fibrosis recommend cleaning and disinfecting nebulizers after each use. We tested two groups of five reusable breath-enhanced nebulizers after 0, 5, 10, 15, 20, 30, 60, 90, 120, 150, and 180 sterilization (baby bottle sterilizer) or cleaning cycles. The nebulizers were operated for 7 min (6 L/min) after loading albuterol (2.5 mg/3 mL), and they were evaluated with and without breathing simulation after cleaning/sterilization (0-180 and 0-60 cycles, respectively). Over the course of 180 cleaning/sterilization cycles, the mean (SD) solution output was 1.33 mL (0.12 mL)/1.29 mL (0.08 mL); the nebulizer mass remaining in the nebulizer was 61.5% (5.2%)/63% (4%); sputtering time was 4.7 min (0.8 min)/4.8 s (0.6 min); inspiratory filter was 19% (3%)/18.5% (2.4%); expiratory filter was 6.7% (1.1%)/6.7% (0.8%); and difference in drug output calculated using the solution output and nebulizer mass was 6.8% (4%)/5.2% (2.9%). Thermal disinfection with a baby-bottle sterilizer did not alter the performance of a reusable breath-enhanced nebulizer. The nebulizer test performed without breathing simulation underestimated its performance. The calculation of the drug output based on the solution output resulted in its overestimation.