Evidence map›Paper›PMID 38276323›Full record

ArticleSensors (Basel, Switzerland)2024

Pressure Sensors: Working Principles of Static and Dynamic Calibration.

José Dias Pereira

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

José Dias PereiraESTSetúbal, Instituto Politécnico de Setúbal, Rua do Vale de Chaves, Estefanilha, 2910-761 Setúbal, Portugal.ORCID 0000-0002-0183-132X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper starts with an overview of the main principles used for pressure measurements, focusing on their usage in industrial applications' domains. Then, the importance of calibration procedures, namely, static and dynamic calibration of pressure sensors, is analyzed. Regarding calibration, it is important to note that there are several applications where the pressure signals to be measured can have large variations in short periods of time. In industrial applications, particularly in continuous production processes, generally, dynamic pressure measurements are less common; however, they are still required in several cases, such as control loops that are very sensitive to pressure variations, even if the frequencies of those variations are in the range of a few tens of hertz, or even lower. The last part of the paper presents the hardware and software of a flexible and low-cost static and dynamic pressure calibrator that also presents the capability to generate arbitrary waveform pressure signals for calibration and testing purposes. The proposed calibrator also includes the following advantages: remote pressure sensing capabilities that can be used to minimize calibration errors, such as those associated with capillary effects and pressure leakages; portability; and low cost. The paper ends with some experimental results obtained with the proposed calibrator.

Indexed as

measurement errorspressure measurementsensorstatic and dynamic calibration

Identifiers

PMID38276323
PMCPMC10818584

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.