Evidence map›Paper›PMID 38275472›Full record

ArticleDiagnostics (Basel, Switzerland)2024

Real-Time Tracheal Ultrasound vs. Capnography for Intubation Confirmation during CPR Wearing a Powered Air-Purifying Respirator in COVID-19 Era.

Seungwan Eun, Hee Yoon, Soo Yeon Kang, Ik Joon Jo, Sejin Heo, Hansol Chang, Guntak Lee, Jong Eun Park, Taerim Kim, Se Uk Lee and 2 more

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Diagnostic Accuracy of Point-of-care Ultrasonography for Confirming Endotracheal Tube Placement in Adults: An Updated Systematic Review and Meta-analysis.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2026
    Article
  2. Clinical Applications of Laryngeal Ultrasonography: A Review.Journal of voice : official journal of the Voice Foundation · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 1 institution in 1 country.

Seungwan EunDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.
Hee YoonDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.ORCID 0000-0002-1297-9813
Soo Yeon KangDepartment of Emergency Medicine, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong-si 14353, Republic of Korea.
Ik Joon JoDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.
Sejin HeoDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.
Hansol ChangDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.ORCID 0000-0002-2624-0008
Guntak LeeDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.
Jong Eun ParkDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.
Taerim KimDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.ORCID 0000-0001-8340-9511
Se Uk LeeDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.
Sung Yeon HwangDepartment of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.
Sun-Young BaekBiomedical Statistics Center, Data Science Research Institute, Research Institute for Future Medicine, Samsung Medical Center, Seoul 06351, Republic of Korea.
Samsung Medical Center · KR

Funding

National Research Foundation of Korea NRF-2022R1C1C1011864
6 · The paper itself

Abstract

This study aimed to compare the accuracy of real-time trans-tracheal ultrasound (TTUS) with capnography to confirm intubation in cardiopulmonary resuscitation (CPR) while wearing a powered air-purifying respirator (PAPR). This setting reflects increased caution due to contagious diseases. This single-center, prospective, comparative study enrolled patients requiring CPR while wearing a PAPR who visited the emergency department of a tertiary medical center from December 2020 to August 2022. A physician performed the TTUS in real time and recorded the tube placement assessment. Another healthcare provider attached waveform capnography to the tube and recorded end-tidal carbon dioxide (EtCO

Indexed as

cardiopulmonary resuscitationCPRemergency department: point-of-care ultrasoundendotracheal intubationpersonal protective equipmentultrasound

Identifiers

PMID38275472
PMCPMC10813934
OpenAlexW4391104682

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.