Evidence map›Paper›PMID 38272181›Full record

ArticleIndian pacing and electrophysiology journal

Retrievable leadless pacemakers (Aveir VR) may be beneficial in adult patients with congenital heart disease.

Zainab Syyeda Rahmat, Daniel Cortez

Abstract read
In one paragraph

Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Dual-Chamber Leadless Pacemaker Implants in the Young.Pacing and clinical electrophysiology : PACE · 2026
    Article
  2. Article
  3. Article
  4. Leadless pacing in young patients.European heart journal supplements : journal of the European Society of Cardiology · 2025
    Article
  5. The leadless pacemaker in ACHD - Cautiously optimistic.Indian pacing and electrophysiology journal
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Zainab Syyeda RahmatDepartment of Electrophysiology, UC Davis Medical Center, USA; Faculty of Medicine, Dow Medical College, Dow University of Health Sciences, Pakistan.
Daniel CortezDepartment of Electrophysiology, UC Davis Medical Center, USA. Electronic address: dancortez@ucdavis.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionCongenital heart disease may present in up to 1.6 % of newborns. Given high burden of pacing need in adult patients with repaired congenital heart disease and availability of different pacing options, more information on outcomes of newer pacemaker types are needed. Retrievable leadless pacemaker implants in adult congenital patients have not been described.

methodsRetrospective review of three Aveir (Abbott) retrievable leadless pacemaker implants were reviewed at the UC Davis Medical Center. All patients underwent implant via femoral access.

resultsAll patients had one deployment only, after mapping prior. No complications occurred. Implant thresholds were 0.5 V (V) @0.2msilliseconds (ms) for patients 1 and 2 and 1 V @0.4 ms for patient 3. With impedances between 500 and 1290 Ω. Sensing was 5.5-8 mV (mV). Follow-up occurred up to one year (for two patients) with similar values overall. The predicted longevities of each device were between 22.6 and >25 years.

conclusionSafety and short-mid-term parameters of retrievable leadless pacemaker implantation is reported in three patients with adult congenital heart disease.

Identifiers

PMID38272181
PMCPMC11010452

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.