ArticleESC heart failure2024
Twelve-month follow-up results from the SIRONA 2 clinical trial.
Article in ESC heart failure, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.
- Effectiveness of remote pulmonary artery pressure estimating in heart failure: systematic review and meta-analysis.Scientific reports · 2024Pooled it
- Advances in cardiac devices and bioelectronics augmented with artificial intelligence.The Journal of physiology · 2026Review
- AI-Enabled Sensor Technologies for Remote Arrhythmic Monitoring in High-Risk Cardiomyopathy Genotypes.Sensors (Basel, Switzerland) · 2026Review
- Subcutaneous sensors for monitoring congestion and to reduce heart failure hospitalizations-a viable middle ground between deep implantable intravascular monitoring devices and wearable technologies?Heart failure reviews · 2025Review
- Noninvasive biometric monitoring technologies for patients with heart failure.Heart failure reviews · 2025Review
- Device-based Strategies for Monitoring Congestion and Guideline-directed Therapy in Heart Failure: The Who, When and How of Personalised Care.Cardiac failure review · 2025Review
- Telemonitoring for Chronic Heart Failure: Narrative Review of the 20-Year Journey From Concept to Standard Care in Germany.Journal of medical Internet research · 2024Review
- A scoping review on advancements in noninvasive wearable technology for heart failure management.NPJ digital medicine · 2024Article
- Remote Monitoring of Cardiac Implantable Electronic Devices in Very Elderly Patients: Advantages and Specific Problems.Journal of cardiovascular development and disease · 2024Review
- Twelve-month follow-up results from the SIRONA 2 clinical trial.ESC heart failure · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 8 institutions in 5 countries.
Funding
Abstract
aimsIn the SIRONA 2 trial, the safety and efficacy of pulmonary artery (PA) pressure (PAP)-guided heart failure (HF) management using a novel PAP sensor were assessed at 30 and 90 days, respectively, and both endpoints were met. The current study examines the prespecified secondary endpoints of safety and accuracy of the PA sensor along with HF hospitalizations and mortality, HF symptoms, functional capacity, quality of life, and patient compliance through 12 months. METHODS AND
resultsSIRONA 2 is a prospective, multi-centre, open-label, single-arm trial evaluating the Cordella™ PA Sensor System in 70 patients with New York Heart Association (NYHA) functional class III HF with a prior HF hospitalization and/or increase of N-terminal pro-brain natriuretic peptide within 12 months of enrolment. Sensor accuracy was assessed and compared with measurements obtained by standard right heart catheterization (RHC). Safety was defined as freedom from prespecified adverse events associated with use of the Cordella PA Sensor System and was assessed in all patients who entered the cath lab for PA sensor implant. HF hospitalizations and mortality, HF symptoms, functional capacity, quality of life, and patient compliance were also assessed. At 12 months, there was good agreement between the Cordella PA Sensor System and RHC, with the average difference for mean PAP being 2.9 ± 7.3 mmHg. The device safety profile was excellent with 98.4% freedom from device/system-related complications. There were no pressure sensor failures. HF hospitalizations and mortality were low with a rate of 0.33 event per patient year. Symptoms as assessed by NYHA (P < 0.0001) and functional capacity as measured by 6 min walk test (P = 0.02) were significantly improved. Patients' adherence to daily transmissions of PAP and vital signs measurements was 95%.
conclusionsLong-term follow-up of the SIRONA 2 trial supports the safety and accuracy of the Cordella PA Sensor System in enabling comprehensive HF management in NYHA class III HF patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.