Evidence map›Paper›PMID 38270636›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2025

The effect of a smaller spacer in the PASCAL Ace on residual mitral valve orifice area.

Michael Paukovitsch, Dominik Felbel, Marijana Tadic, Mirjam Keßler, Jinny Scheffler, Matthias Gröger, Sinisa Markovic, Wolfgang Rottbauer, Leonhard Moritz Schneider

Abstract read
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Michael PaukovitschUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
Dominik FelbelUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
Marijana TadicUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
Mirjam KeßlerUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
Jinny SchefflerUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
Matthias GrögerUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
Sinisa MarkovicUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
Wolfgang RottbauerUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany. wolfgang.rottbauer@uniklinik-ulm.de.ORCID http://orcid.org/0000-0003-4725-6217
Leonhard Moritz SchneiderUlm University Heart Center, Department of Cardiology, Albert-Einstein-Allee 23, 89081, Ulm, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMitral transcatheter edge-to-edge repair (M-TEER) is an established treatment for functional mitral regurgitation (FMR) associated with a risk of creating iatrogenic stenosis.

objectivesTo investigate the impact of the P10 and its larger spacer compared to the narrower Ace and its smaller spacer on reduction of mitral valve orifice area (MVOA) during M-TEER.

methodsConsecutive patients undergoing M-TEER for treatment of severe FMR were screened retrospectively. Patients with a single PASCAL device implantation within the central segments of the MV leaflets, non-complex anatomy, and baseline MVOA ≥ 3.5cm

resultsSeventy-two patients (81.0 years, IQR {74.3-85.0}) were included. In 32 patients, the P10 was implanted (44.4%). MR severity (p = 0.66), MR reduction (p = 0.73), and body surface area (p = 0.56) were comparable. Baseline MVOA tended to be smaller in P10 patients with the larger spacer (5.0 ± 1.1 vs. 5.4 ± 1.3cm

conclusionIn FMR patients with non-complex anatomy, the larger spacer of the P10 maintains greater MVOA with similar MR reduction. Hence, the use of the PASCAL Ace device in patients with small MVOAs might correlate with a risk of both clinically relevant orifice reduction and even iatrogenic stenosis.

Indexed as

Cardiac CatheterizationHeart Valve ProsthesisHeart Valve Prosthesis ImplantationMitral ValveMitral Valve InsufficiencyAgedAged, 80 and overEchocardiography, Three-DimensionalEchocardiography, TransesophagealFemaleHumansMaleProsthesis DesignRetrospective StudiesSeverity of Illness IndexTreatment OutcomeIatrogenic stenosisMitral valve edge-to-edge repairMitral valve orifice area

Identifiers

PMID38270636
PMCPMC12202501

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.