Repeatability and reproducibility of quantitative OCT angiography measurements from table-top and portable Flex Spectralis devices.

Arathi Ponugoti, Hoan Ngo, Sandra Stinnett, Michael P Kelly, Lejla Vajzovic

Abstract read
PubMed Publisher
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Minimum perceptual time (MPT). Repeatability and reproducibility of variables applied to "sports vision".Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Arathi PonugotiDepartment of Ophthalmology, Duke University Eye Center, 2351 Erwin Rd, Durham, NC, 27705, USA. ap212@duke.edu.ORCID http://orcid.org/0000-0001-9207-0732
Hoan NgoSchool of Biomedical Engineering, International University-VNU HCMC, Ho Chi Minh City, Vietnam.
Sandra StinnettDepartment of Ophthalmology, Duke University Eye Center, 2351 Erwin Rd, Durham, NC, 27705, USA.
Michael P KellyDepartment of Ophthalmology, Duke University Eye Center, 2351 Erwin Rd, Durham, NC, 27705, USA.
Lejla VajzovicDepartment of Ophthalmology, Duke University Eye Center, 2351 Erwin Rd, Durham, NC, 27705, USA.ORCID http://orcid.org/0000-0002-4469-6834

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe recent development of a portable investigational handheld OCT-angiography (OCTA) device has allowed for expansion of imaging into the operating room (OR) in addition to standard in-clinic imaging. The aim of this study was to assess intravisit repeatability and intervisit reproducibility of retinal microvasculature measures and central retinal thickness for in-clinic table-top and portable OR compatible OCTA devices.

methodsRepeated 10 × 10 OCTA images were acquired in 20 healthy adult participants on two separate visit days using Spectralis spectral-domain OCTA table-top and investigational armature suspended Flex systems. Intravisit and intervisit intraclass correlation coefficients and average absolute percent difference were calculated for quantitative microvasculature measures and CRT.

results120 OCTA images were acquired from 20 subjects (n = 20, mean age 26.7 ± 1.61 years, range 24-30 years) with both devices across two separate imaging days. FAZ and CRT measurements had near complete intravisit and intervisit agreement with ICCs between .97 and 1 for both table-top (FAZ ICC .97, .97; CRT ICC .98-1, .98-.99) and Flex (FAZ ICC .97, .95; CRT ICC .99-1, .98-.99) devices. Vessel density measures demonstrated greater variance with only fair to strong agreement (ICC .32-.75) and average absolute percent differences ranging from 2.96 to 6.63%.

conclusionFAZ and CRT measures for both devices demonstrated high repeatability and reproducibility; retinal vessel density measures demonstrated less. Differences of less than 7% for retinal microvasculature measurements across time and devices are most likely attributable to expectable variance between repeat scans.

Indexed as

Fluorescein AngiographyRetinal VesselsTomography, Optical CoherenceAdultEquipment DesignFemaleFundus OculiHealthy VolunteersHumansMaleReproducibility of ResultsYoung AdultImaging and instrumentationOptical coherence tomographyOptical coherence tomography angiographyRetinaRetinal imaging

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.