Evidence map›Paper›PMID 38267970›Full record

ArticleBMC surgery2024

Initial experience of 3-dimensional exoscope in decompression of massive lumbar disc herniation.

Fanglong Song, Zhiqiang Zhou, Xiaozhong Zhou, Haowei Wu, Bingchen Shan, Zhentao Zhou, Jun Dai, Fengxian Jiang

Open access · goldAbstract read
In one paragraph

Article in BMC surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 99% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Fanglong Song *Department of Orthopedic Surgery, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu District, Suzhou, 215004, Jiangsu, China.
Zhiqiang Zhou *Department of Orthopedic Surgery, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu District, Suzhou, 215004, Jiangsu, China.
Xiaozhong ZhouDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu District, Suzhou, 215004, Jiangsu, China.
Haowei WuDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu District, Suzhou, 215004, Jiangsu, China.
Bingchen ShanDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu District, Suzhou, 215004, Jiangsu, China.
Zhentao ZhouDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu District, Suzhou, 215004, Jiangsu, China.
Jun DaiDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu District, Suzhou, 215004, Jiangsu, China. daijun@suda.edu.cn.
Fengxian JiangDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu District, Suzhou, 215004, Jiangsu, China. jiangfengxian@suda.edu.cn.
Soochow University · CNSecond Affiliated Hospital of Soochow University · CN

Funding

National Natural Science Foundation of China 81902241Social Development Key Programs of Jiangsu Province-Advanced Clinical Technology BE2019662、BE2018656Suzhou Special Foundation for the Key Diseases Diagnosis and Treatment LCZX201904, LCZX201708
6 · The paper itself

Abstract

objectivesTo investigate the effect of a three-dimensional (3D) exoscope for decompression of single-segment massive lumbar disc herniation (LDH).

methodsThe study included 56 consecutive patients with single segment massive LDH who underwent decompression assisted by a 3D exoscope from October 2019 to October 2022 at a university hospital. The analysis was based on comparison of perioperative metrics including decompression time, estimated blood loss (EBL) during decompression and postoperative length of stay (PLS); clinical outcomes including assessment using the visual analogue scale (VAS) and the Oswestry disability index (ODI); and incidence of reoperation and complications.

resultsThe mean decompression time was 28.35 ± 8.93 min (lumbar interbody fusion (LIF)) and 15.50 ± 5.84 min (fenestration discectomy (LOVE surgery)), the mean EBL during decompression was 42.65 ± 12.42 ml (LIF) and 24.32 ± 8.61 ml (LOVE surgery), and the mean PLS was 4.56 ± 0.82 days (LIF) and 2.00 ± 0.65 days (LOVE surgery). There were no complications such as cerebrospinal fluid leakage, nerve root injury and epidural hematoma. All patients who underwent decompression assisted by a 3D exoscope were followed up for 6 months. At the last follow-up, the VAS and ODI scores were significantly improved from the preoperative period to the last follow-up (P < 0.05).

conclusionsA 3D exoscope provides a visually detailed, deep and clear surgical field, which makes decompression safer and more effective and reduces short-term complications. A 3D exoscope may be a good assistance tool during decompression for single-segment massive LDH.

Indexed as

Hematoma, Epidural, CranialIntervertebral Disc DisplacementCerebrospinal Fluid LeakDecompressionHospitals, UniversityHumansDecompressionDegenerative disc diseaseMassive lumbar disc herniationMinimally invasive surgeryThree-dimensional exoscope

Identifiers

PMID38267970
PMCPMC10809480
OpenAlexW4391166532

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.