Evidence map›Paper›PMID 38267659›Full record

ArticleClinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico2024

On the need of in vivo verifications as quality control for intraoperative electron radiotherapy in breast cancer.

Carla Cases, Gabriela Oses, Antonio Herreros, Jordi Tarrats-Rosell, Sara Moreno, Meritxell Mollà

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. SAFE-IOERT prospective study: clinical outcomes of exclusive intraoperative radiotherapy in early breast cancer according to molecular subtype and tumor-infiltrating lymphocytes.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Carla CasesDepartment of Radiation Oncology, Hospital Clínic, Carrer de Villarroel 170, 08036, Barcelona, Spain. cases@clinic.cat.ORCID http://orcid.org/0000-0003-2110-9016
Gabriela OsesDepartment of Radiation Oncology, Hospital Clínic, Carrer de Villarroel 170, 08036, Barcelona, Spain.
Antonio HerrerosDepartment of Radiation Oncology, Hospital Clínic, Carrer de Villarroel 170, 08036, Barcelona, Spain.
Jordi Tarrats-RosellDepartment of Radiation Oncology, Hospital Clínic, Carrer de Villarroel 170, 08036, Barcelona, Spain.
Sara MorenoDepartment of Radiation Oncology, Hospital Clínic, Carrer de Villarroel 170, 08036, Barcelona, Spain.
Meritxell MollàDepartment of Radiation Oncology, Hospital Clínic, Carrer de Villarroel 170, 08036, Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIntraoperative electron radiotherapy (IOERT) is a technique aiming to deliver radiotherapy during oncological surgery. In breast IOERT, the applicator and shielding disc placement are correlated with organs at risk (OAR) irradiation, in vivo verification of these parameters is scarcely reported. The aim of our study is to report and analyze possible causes of the misalignment using radiochromic films and compare our results to others reported in the bibliography.

methodsFrom November 2019 to April 2023, in vivo verifications were performed for 33 patients. IOERT was performed using a LIAC 10 MeV (Sordina, Italy) electron accelerator. We attached a radiochromic film to the upper side of the polytetrafluoroethylene cover of the shielding disc. The percentage of the irradiation area outside the disc was recorded and various parameters (applicator angulations, prescription depth, tumor location and breast size) were analyzed to find possible correlations.

resultsFor 29 patients, 20 Gy were prescribed while 10 Gy were prescribed to 4 patients. The average irradiated area outside the disc was 19% (0-56%) corresponding to a surface of 4.5 cm

conclusionThis study confirms the presence and magnitude of the misalignments. We strongly recommend in vivo verifications as a quality check during IOERT procedures. The misalignment has no correlation with tumor localization parameters, so the solution could be based on technical improvements of the applicator.

Indexed as

Breast NeoplasmsElectronsAdultAgedFemaleHumansIntraoperative CareMiddle AgedOrgans at RiskParticle AcceleratorsQuality ControlRadiotherapy DosageRadiotherapy Planning, Computer-AssistedBreastGraphchromicIn vivo verificationIOERT

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.