Evidence map›Paper›PMID 38266123›Full record

SynthesisBJS open2024

Accuracy of point-of-care testing devices for haemoglobin in the operating room: meta-analysis.

Hilalion San Ahn, Tori Lenet, Richard W D Gilbert, Ranjeeta Mallick, Julie L V Shaw, Dean A Fergusson, Daniel I McIsaac, Guillaume Martel

Open access · goldAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in BJS open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Hilalion San AhnDepartment of Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada.
Tori LenetDepartment of Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada.
Richard W D GilbertDepartment of Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada.
Ranjeeta MallickClinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada.
Julie L V ShawDepartment of Pathology and Laboratory Medicine, University of Ottawa, Ottawa, ON, Canada.ORCID 0000-0003-3983-8487
Dean A FergussonClinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada.
Daniel I McIsaacClinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada.ORCID 0000-0002-8543-1859
Guillaume MartelDepartment of Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada.ORCID 0000-0002-1242-2601
University of Ottawa · CAOttawa Hospital · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPoint-of-care tests (POCT) for haemoglobin are increasingly used to guide intraoperative transfusion. However, their accuracy compared to central laboratory tests is unknown. The objective was to perform a systematic review and meta-analysis of method comparison studies assessing the accuracy of POCT versus central laboratory haemoglobin tests in patients undergoing surgery.

methodsElectronic databases were searched from inception to April 2020 (updated August 2023). Any methodological approach comparing haemoglobin measurements between POCT and central laboratory in patients undergoing surgery under anaesthesia in the operating room were included. Data abstraction was guided by PRISMA and risk of bias was assessed by QUADAS-2. Data were extracted independently and in duplicate by two reviewers. Outcomes included mean differences between POCT and central laboratory haemoglobin with associated standard deviations and 95% limits of agreement (LOA).

resultsOf 3057 citations, 34 studies were included (n = 2427, 6857 paired measurements). Several devices were compared (pulse co-oximetry, n = 25; HemoCue, n = 10; iSTAT, n = 6; blood gas analysers, n = 10; haematology analyser, n = 2). Median sample size was 41 patients, and 11 studies were funded by device manufacturers. Fifteen of 34 studies had low risk of bias. Pooled mean differences (95% LOA) were: pulse co-oximeters 2.3 g/l (-25.2-29.8), HemoCue -0.3 g/l (-11.1-10.5), iSTAT -0.3 g/l (-8.4-7.8) and blood gas analysers -2.6 g/l (-17.8-12.7).

conclusionAll POCT examining intraoperative haemoglobin measurement yielded pooled mean difference LOAs larger than the allowable limit difference of ±4 g/dl. Intraoperative haemoglobin measured by POCT should not be considered interchangeable with central laboratory values and caution is necessary when using these tests to guide intraoperative transfusion.

Indexed as

HemoglobinsOperating RoomsAnesthesiaHumansHemoglobins

Identifiers

PMID38266123
PMCPMC10807999
OpenAlexW4391188200

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.