Evidence map›Paper›PMID 38265463›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Risk of reverse golf club deformity with medial plating of distal femur fracture.

Tyler J Thorne, Graham J DeKeyser, Ian Clapp, Justin M Haller

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Dual Plating of Distal Femoral Fractures.JBJS essential surgical techniques
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Tyler J ThorneDepartment of Orthopaedic Surgery, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.
Graham J DeKeyserOregon Health and Sciences University, Portland, OR, USA.
Ian ClappDepartment of Orthopaedic Surgery, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.
Justin M HallerDepartment of Orthopaedic Surgery, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA. justin.haller@hsc.utah.edu.ORCID http://orcid.org/0000-0002-8269-3925
University of Utah · USOregon Health & Science University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study described a deformity induced by medial plating of supracondylar distal femur fractures using plates that are precontoured for other anatomic locations. MATERIALS AND

methodsOTA/AO 33A fractures were created in 12 sawbone femurs and fixed with either a proximal humerus locking plate (PH), an ipsilateral lateral tibial plateau plate (LTP), or an ipsilateral medial distal tibial plate (MDT). A motion capture system measured changes in length and rotation of the distal femur as the plate was applied. Each plate underwent four trials and the mean and standard deviation (SD) for each measurement was reported. An analysis of variance with post hoc Tukey test compared malreduction measures between plate types.

resultsAll plates consistently created a varus deformity. There was lateral lengthening with a compensatory medial shortening and an increase in the lateral distal femoral angle. The distal fracture fragment was laterally translated, and internally rotated. The PH plate had significantly greater lateral length (27.39 mm SD 4.78, p = 0.007), shorter medial length (13.57 mm SD 4.99, p = 0.028), greater lateral translation (28.82 mm SD 5.70, p = 0.010) and greater widening of the lateral distal femoral angle (28.54° SD 4.98, p < 0.001) than the LTP and MDT plates. The MDT plate had significantly greater angulation anteriorly (8.40° SD 1.07, p < 0.001) and laterally (7.63° SD 3.10, p = 0.002) than the PH and LTP plates. There was no significant difference between plates in internal rotation (PH: 3.07° SD 2.79; LTP: 2.05° SD 1.05; MDT 3.81° SD 3.56; p = 0.659).

conclusionWhen dual plating supracondylar distal femur fractures, poor plate positioning and a mismatch between plate contour and the slope of the medial distal femur can lead to varus angulation, internal rotation, and lateral translation or a "reverse golf club deformity". After comparing three types of precontoured plates, the authors recommend initial evaluation of the ipsilateral proximal tibial plate when placing a plate along the medial distal femur. LEVEL OF EVIDENCE: IV.

Indexed as

Femoral FracturesFemoral Fractures, DistalGolfBone PlatesFemurFracture Fixation, InternalHumansDeformityDistal femurDual platingMalreductionMalunionMedial platingTrauma

Identifiers

PMID38265463
OpenAlexW4391169025

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.