Evidence map›Paper›PMID 38264434›Full record

ArticleJournal of biomedical optics2024

Combined flat-field and frequency filter approach to correcting artifacts of multichannel two-photon microscopy.

Thomas Knapp, Natzem Lima, Noelle Daigle, Suzann Duan, Juanita L Merchant, Travis W Sawyer

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Thomas KnappUniversity of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States.ORCID 0000-0003-3304-1645
Natzem LimaUniversity of Arizona, Wyant College of Optical Sciences, Tucson, Arizona, United States.ORCID 0000-0002-3668-4374
Noelle DaigleUniversity of Arizona, Wyant College of Optical Sciences, Tucson, Arizona, United States.ORCID 0009-0008-5941-8264
Suzann DuanUniversity of Arizona, College of Medicine, Tucson, Arizona, United States.ORCID 0000-0002-5129-0736
Juanita L MerchantUniversity of Arizona, College of Medicine, Tucson, Arizona, United States.ORCID 0000-0002-6559-8184
Travis W SawyerUniversity of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States.ORCID 0000-0002-6911-0289
University of Arizona · US

Funding

Computational and Mathematical Modeling of Biomedical SystemsT32GM132008 · NIGMS · UNIVERSITY OF ARIZONA · PI Ryan Gutenkunst, JOANNA MASEL · 2019 to 2026
$2.3M
NIGMS NIH HHS T32 GM132008
6 · The paper itself

Abstract

Significance: Multiphoton microscopy (MPM) is a useful biomedical imaging tool for its ability to probe labeled and unlabeled depth-resolved tissue biomarkers at high resolution. Automated MPM tile scanning allows for whole-slide image acquisition but can suffer from tile-stitching artifacts that prevent accurate quantitative data analysis. Aim: We have investigated postprocessing artifact correction methods using ImageJ macros and custom Python code. Quantitative and qualitative comparisons of these methods were made using whole-slide MPM autofluorescence and second-harmonic generation images of human duodenal tissue. Approach: Image quality after artifact removal is assessed by evaluating the processed image and its unprocessed counterpart using the root mean square error, structural similarity index, and image histogram measurements. Results: Consideration of both quantitative and qualitative results suggest that a combination of a custom flat-field-based correction and frequency filtering processing step provide improved artifact correction when compared with each method used independently to correct for tiling artifacts of tile-scan MPM images. Conclusions: While some image artifacts remain with these methods, further optimization of these processing steps may result in computational-efficient methods for removing these artifacts that are ubiquitous in large-scale MPM imaging. Removal of these artifacts with retention of the original image information would facilitate the use of this imaging modality in both research and clinical settings, where it is highly useful in collecting detailed morphologic and optical properties of tissue.

Indexed as

ArtifactsMicroscopyHumansPhotonsautofluorescenceimage artifactsimage processingmultiphoton microscopyscanning microscopy

Identifiers

PMID38264434
PMCPMC10804314
OpenAlexW4391131114

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.