ArticleAdvances in orthopedics2024
Two-Year Outcomes of Novel Dual-Mobility Implant in Primary Total Hip Arthroplasty.
Article in Advances in orthopedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Satisfactory Survivorship and Clinical Outcomes After Acetabular Revision With the Three-Dimensional-Printed Porous Metal Monoblock Dual-Mobility Cup: A Retrospective Case Series With Mean 3 Years Follow-Up.Arthroplasty today · 2026Article
- Midterm Outcomes of Revision Total Hip Arthroplasty With Cementation of a Monoblock Dual-Mobility Bearing Cup in a Porous Revision Acetabular Shell.Arthroplasty today · 2026Article
- Minimum Two-Year Outcomes of the Zimmer G7 Modular Dual Mobility Cup in Primary Total Hip Arthroplasty: Survivorship, Complications, Clinical and Radiographic Results.Journal of clinical medicine · 2025Article
- Comparison of Short-Term Outcomes and Survivorship of Three Modular Dual Mobility Implants in Primary Total Hip Surgery.Journal of clinical medicine · 2025Article
- Radiological assessment of cup anteversion with a novel 3D-printed highly-porous titanium dual mobility cup.Journal of orthopaedic surgery and research · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Dual-mobility (DM) implants for total hip arthroplasty (THA) have gained popularity due to their potential to reduce hip instability and dislocation events that may lead to revision surgery. These implants consist of a femoral head articulated within a polyethylene liner, which articulates within an outer acetabular shell, creating a dual-bearing surface. Our study aimed to report our observations on the survivorship of a novel DM implant for primary total hip arthroplasty at two years. Methods: We conducted a retrospective, multicenter study to assess the clinical outcomes of patients undergoing a THA with a novel DM implant (OR3O acetabular system™, Smith & Nephew, Inc., Memphis, TN) from January 2020 to September 2021. Patient demographics, surgical information, and survivorship data were collected from medical records for patients with a minimum of two years of follow-up. Primary outcomes included overall implant survivorship at two years as well as aseptic survivorship, revision rates of the DM acetabular shell, and average time to revision. Patient-reported outcomes were collected in the form of HOOS JR. Results: A total of 250 hips in 245 patients had a minimum two-year follow-up. Primary osteoarthritis (80%) was the most common indication for index THA. The average aseptic survivorship of the DM acetabular components at two years for the cohort was 98.4% and survivorship of the acetabular implants overall was 97.6%. There were a total of four (1.6%) aseptic revisions of the DM acetabular component. Reasons for aseptic acetabular revision included one case of instability, one intraprosthetic dislocation, one periprosthetic acetabular fracture, and one malpositioned acetabular cup resulting in impingement. The mean time of follow-up was 893.9 days. Eighty-seven patients had preoperative and two-year HOOS JR available. HOOS JR improved by an average of 38.5 points. Conclusion: This novel DM acetabular implant demonstrates excellent survivorship at two years follow-up with low rates of instability and intraprosthetic dislocation and no episodes of metal-on-metal corrosion. Use of the DM implant demonstrated clinically relevant improvements in patient-reported outcomes at two years.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.