Evidence map›Paper›PMID 38264013›Full record

ArticleAdvances in orthopedics2024

Two-Year Outcomes of Novel Dual-Mobility Implant in Primary Total Hip Arthroplasty.

Benjamin C Schaffler, Hayley E Raymond, Collin S Black, Akram A Habibi, Mallory Ehlers, Stephen T Duncan, Ran Schwarzkopf

Abstract read
In one paragraph

Article in Advances in orthopedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Benjamin C SchafflerNew York University Langone Orthopedic Hospital, New York, NY, USA.ORCID https://orcid.org/0000-0002-8610-2547
Hayley E RaymondNew York University Langone Orthopedic Hospital, New York, NY, USA.ORCID https://orcid.org/0000-0002-0411-9514
Collin S BlackUniversity of Kentucky, Department of Orthopaedic Surgery, Lexington, KY, USA.ORCID https://orcid.org/0000-0003-3528-6363
Akram A HabibiNew York University Langone Orthopedic Hospital, New York, NY, USA.ORCID https://orcid.org/0000-0002-3776-1888
Mallory EhlersNew York University Langone Orthopedic Hospital, New York, NY, USA.ORCID https://orcid.org/0009-0006-4044-4505
Stephen T DuncanUniversity of Kentucky, Department of Orthopaedic Surgery, Lexington, KY, USA.ORCID https://orcid.org/0000-0002-2849-0326
Ran SchwarzkopfNew York University Langone Orthopedic Hospital, New York, NY, USA.ORCID https://orcid.org/0000-0003-0681-7014

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Dual-mobility (DM) implants for total hip arthroplasty (THA) have gained popularity due to their potential to reduce hip instability and dislocation events that may lead to revision surgery. These implants consist of a femoral head articulated within a polyethylene liner, which articulates within an outer acetabular shell, creating a dual-bearing surface. Our study aimed to report our observations on the survivorship of a novel DM implant for primary total hip arthroplasty at two years. Methods: We conducted a retrospective, multicenter study to assess the clinical outcomes of patients undergoing a THA with a novel DM implant (OR3O acetabular system™, Smith & Nephew, Inc., Memphis, TN) from January 2020 to September 2021. Patient demographics, surgical information, and survivorship data were collected from medical records for patients with a minimum of two years of follow-up. Primary outcomes included overall implant survivorship at two years as well as aseptic survivorship, revision rates of the DM acetabular shell, and average time to revision. Patient-reported outcomes were collected in the form of HOOS JR. Results: A total of 250 hips in 245 patients had a minimum two-year follow-up. Primary osteoarthritis (80%) was the most common indication for index THA. The average aseptic survivorship of the DM acetabular components at two years for the cohort was 98.4% and survivorship of the acetabular implants overall was 97.6%. There were a total of four (1.6%) aseptic revisions of the DM acetabular component. Reasons for aseptic acetabular revision included one case of instability, one intraprosthetic dislocation, one periprosthetic acetabular fracture, and one malpositioned acetabular cup resulting in impingement. The mean time of follow-up was 893.9 days. Eighty-seven patients had preoperative and two-year HOOS JR available. HOOS JR improved by an average of 38.5 points. Conclusion: This novel DM acetabular implant demonstrates excellent survivorship at two years follow-up with low rates of instability and intraprosthetic dislocation and no episodes of metal-on-metal corrosion. Use of the DM implant demonstrated clinically relevant improvements in patient-reported outcomes at two years.

Identifiers

PMID38264013
PMCPMC10805547

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.