Evidence map›Paper›PMID 38263441›Full record

ArticleScientific reports2024

Optimizing the performance of convolutional neural network for enhanced gesture recognition using sEMG.

Hassan Ashraf, Asim Waris, Syed Omer Gilani, Uzma Shafiq, Javaid Iqbal, Ernest Nlandu Kamavuako, Yaakoub Berrouche, Olivier Brüls, Mohamed Boutaayamou, Imran Khan Niazi

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hassan AshrafLaboratory of Movement Analysis (LAM-Motion Lab), University of Liège, Liège, Belgium.
Asim WarisDepartment of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering (SMME), National University of Science and Technology (NUST), Islamabad, 44000, Pakistan. asim.waris@smme.nust.edu.pk.
Syed Omer GilaniDepartment of Electrical, Computer and Biomedical Engineering, Faculty of Engineering, Abu Dhabi University, Abu Dhabi, United Arab Emirates.
Uzma ShafiqDepartment of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering (SMME), National University of Science and Technology (NUST), Islamabad, 44000, Pakistan.
Javaid IqbalDepartment of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering (SMME), National University of Science and Technology (NUST), Islamabad, 44000, Pakistan.
Ernest Nlandu KamavuakoDepartment of Informatics, King's College London, London, WC2R 2LS, UK.
Yaakoub BerroucheLIS Laboratory, Department of Electronics, Faculty of Technology, Ferhat Abbas University Setif 1, Setif, Algeria.
Olivier BrülsLaboratory of Movement Analysis (LAM-Motion Lab), University of Liège, Liège, Belgium.
Mohamed BoutaayamouLaboratory of Movement Analysis (LAM-Motion Lab), University of Liège, Liège, Belgium.
Imran Khan NiaziNew Zealand College of Chiropractic, Auckland, New Zealand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Deep neural networks (DNNs) have demonstrated higher performance results when compared to traditional approaches for implementing robust myoelectric control (MEC) systems. However, the delay induced by optimising a MEC remains a concern for real-time applications. As a result, an optimised DNN architecture based on fine-tuned hyperparameters is required. This study investigates the optimal configuration of convolutional neural network (CNN)-based MEC by proposing an effective data segmentation technique and a generalised set of hyperparameters. Firstly, two segmentation strategies (disjoint and overlap) and various segment and overlap sizes were studied to optimise segmentation parameters. Secondly, to address the challenge of optimising the hyperparameters of a DNN-based MEC system, the problem has been abstracted as an optimisation problem, and Bayesian optimisation has been used to solve it. From 20 healthy people, ten surface electromyography (sEMG) grasping movements abstracted from daily life were chosen as the target gesture set. With an ideal segment size of 200 ms and an overlap size of 80%, the results show that the overlap segmentation technique outperforms the disjoint segmentation technique (p-value < 0.05). In comparison to manual (12.76 ± 4.66), grid (0.10 ± 0.03), and random (0.12 ± 0.05) search hyperparameters optimisation strategies, the proposed optimisation technique resulted in a mean classification error rate (CER) of 0.08 ± 0.03 across all subjects. In addition, a generalised CNN architecture with an optimal set of hyperparameters is proposed. When tested separately on all individuals, the single generalised CNN architecture produced an overall CER of 0.09 ± 0.03. This study's significance lies in its contribution to the field of EMG signal processing by demonstrating the superiority of the overlap segmentation technique, optimizing CNN hyperparameters through Bayesian optimization, and offering practical insights for improving prosthetic control and human-computer interfaces.

Indexed as

Computer SystemsGesturesBayes TheoremElectromyographyHumansNeural Networks, Computer

Identifiers

PMID38263441
PMCPMC10805798

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.