Evidence map›Paper›PMID 38260429›Full record

ArticlebioRxiv : the preprint server for biology2024

Data-driven system matrix manipulation enabling fast functional imaging and intra-image nonrigid motion correction in tomography.

Peng Hu, Xin Tong, Li Lin, Lihong V Wang

Abstract readPreprint
In one paragraph

Article in bioRxiv : the preprint server for biology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Peng HuCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA.ORCID 0000-0002-2933-1239
Xin TongCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA.
Li LinCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA.
Lihong V WangCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA.

Funding

Massively parallel high-speed 3D functional photoacoustic computed tomography of the adult human brainU01EB029823 · NIBIB · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI WANG, DANNY JJ, WANG, LIHONG · 2020 to 2024
$6.7M
High-speed panoramic 3D photoacoustic computed tomography of the breastR35CA220436 · NCI · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI WANG, LIHONG · 2018 to 2024
$6.4M
Safe, rapid & functional pediatric brain imaging using photoacoustic computed tomographyR01NS102213 · NINDS · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI ANASTASIO, MARK A, WANG, LIHONG · 2017 to 2021
$3.0M
NCI NIH HHS R35 CA220436NIBIB NIH HHS U01 EB029823NINDS NIH HHS R01 NS102213
6 · The paper itself

Abstract

Tomographic imaging modalities are described by large system matrices. Sparse sampling and tissue motion degrade system matrix and image quality. Various existing techniques improve the image quality without correcting the system matrices. Here, we compress the system matrices to improve computational efficiency (e.g., 42 times) using singular value decomposition and fast Fourier transform. Enabled by the efficiency, we propose (1) fast sparsely sampling functional imaging by incorporating a densely sampled prior image into the system matrix, which maintains the critical linearity while mitigating artifacts and (2) intra-image nonrigid motion correction by incorporating the motion as subdomain translations into the system matrix and reconstructing the translations together with the image iteratively. We demonstrate the methods in 3D photoacoustic computed tomography with significantly improved image qualities and clarify their applicability to X-ray CT and MRI or other types of imperfections due to the similarities in system matrices.

Identifiers

PMID38260429
PMCPMC10802502

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.