Evidence map›Paper›PMID 38258233›Full record

ArticleMicromachines2024

Compact Micro-Coriolis Mass-Flow Meter with Optical Readout.

Mahdieh Yariesbouei, Remco G P Sanders, Remco J Wiegerink, Joost C Lötters

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mahdieh YariesboueiIntegrated Devices and Systems, University of Twente, 7522 NB Enschede, The Netherlands.
Remco G P SandersIntegrated Devices and Systems, University of Twente, 7522 NB Enschede, The Netherlands.
Remco J WiegerinkIntegrated Devices and Systems, University of Twente, 7522 NB Enschede, The Netherlands.ORCID 0000-0001-5571-739X
Joost C LöttersIntegrated Devices and Systems, University of Twente, 7522 NB Enschede, The Netherlands.

Funding

Bronkhorst (Netherlands)TKI HTSM
6 · The paper itself

Abstract

This paper presents the first nickel-plated micro-Coriolis mass-flow sensor with integrated optical readout. The sensor consists of a freely suspended tube made of electroplated nickel with a total length of 60 mm, an inner diameter of 580 µm, and a wall thickness of approximately 8 µm. The U-shaped tube is actuated by Lorentz forces. An optical readout consisting of two LEDs and two phototransistors is used to detect the tube motion. Mass-flow measurements were performed at room temperature with water and isopropyl alcohol for flows up to 200 g/h and 100 g/h, respectively. The measured resonance frequencies were 1.67 kHz and 738 Hz for water and 1.70 kHz and 752 Hz for isopropyl alcohol for the twist and swing modes, respectively. The measured phase shift between the two readout signals shows a linear response to mass flow with very similar sensitivities for water and isopropyl alcohol of 0.41mdegg/h and 0.43 mdegg/h, respectively.

Indexed as

compact micro-Coriolis mass-flow meternickel electroplated tubeoptical readout

Identifiers

PMID38258233
PMCPMC10821207

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.