Evidence map›Paper›PMID 38258214›Full record

ArticleMicromachines2023

Control Software Design for a Multisensing Multicellular Microscale Gas Chromatography System.

Qu Xu, Xiangyu Zhao, Yutao Qin, Yogesh B Gianchandani

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Qu XuCenter for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, MI 48109, USA.
Xiangyu ZhaoCenter for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, MI 48109, USA.ORCID 0000-0002-3525-9747
Yutao QinCenter for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, MI 48109, USA.ORCID 0000-0003-4589-4485
Yogesh B GianchandaniCenter for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, MI 48109, USA.ORCID 0000-0003-2281-3937
University of Michigan · US

Funding

Intelligence Advanced Research Projects Activity (IARPA) FA8650-19-C-9105
6 · The paper itself

Abstract

Microscale gas chromatography (μGC) systems are miniaturized instruments that typically incorporate one or several microfabricated fluidic elements; such systems are generally well suited for the automated sampling and analysis of gas-phase chemicals. Advanced μGC systems may incorporate more than 15 elements and operate these elements in different coordinated sequences to execute complex operations. In particular, the control software must manage the sampling and analysis operations of the μGC system in a time-sensitive manner; while operating multiple control loops, it must also manage error conditions, data acquisition, and user interactions when necessary. To address these challenges, this work describes the investigation of multithreaded control software and its evaluation with a representative μGC system. The μGC system is based on a progressive cellular architecture that uses multiple μGC cells to efficiently broaden the range of chemical analytes, with each cell incorporating multiple detectors. Implemented in Python language version 3.7.3 and executed by an embedded single-board computer, the control software enables the concurrent control of heaters, pumps, and valves while also gathering data from thermistors, pressure sensors, capacitive detectors, and photoionization detectors. A graphical user interface (UI) that operates on a laptop provides visualization of control parameters in real time. In experimental evaluations, the control software provided successful operation and readout for all the components, including eight sets of thermistors and heaters that form temperature feedback loops, two sets of pressure sensors and tunable gas pumps that form pressure head feedback loops, six capacitive detectors, three photoionization detectors, six valves, and an additional fixed-flow gas pump. A typical run analyzing 18 chemicals is presented. Although the operating system does not guarantee real-time operation, the relative standard deviations of the control loop timings were <0.5%. The control software successfully supported >1000 μGC runs that analyzed various chemical mixtures.

Indexed as

C#embedded systemsfirmwareGPIOGUII2CJSONmiddlewareportable GCPythonSMbus

Identifiers

PMID38258214
PMCPMC10818470
OpenAlexW4390471225

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.