Evidence map›Paper›PMID 38258164›Full record

ArticleMicromachines2023

A Gas Flow Measurement System Based on Lead Zirconate Titanate Piezoelectric Micromachined Ultrasonic Transducer.

Tao Liu, Zhihao Li, Jiahuan Zhang, Dongxiao Li, Hanjie Dou, Pengfan Wu, Jiaqian Yang, Wangyang Zhang, Xiaojing Mu

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Tao LiuKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.
Zhihao LiKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.
Jiahuan ZhangKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.
Dongxiao LiKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.ORCID 0000-0002-6560-5540
Hanjie DouKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.
Pengfan WuKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.
Jiaqian YangKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.
Wangyang ZhangKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.
Xiaojing MuKey Laboratory of Optoelectronic Technology and Systems of Ministry of Education, International Research and Development Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.

Funding

Fundamental Research Funds for the Central Universities No. 2022CDJKYJH059National Key Research and Development Program of China No. 2021YFB2012101Science Fund for Distinguished Young Scholars of Chongqing No. CSTB2022 NSCQJQX0006
6 · The paper itself

Abstract

Ultrasonic flowmeter is one of the most widely used devices in flow measurement. Traditional bulk piezoelectric ceramic transducers restrict their application to small pipe diameters. In this paper, we propose an ultrasonic gas flowmeter based on a PZT piezoelectric micromachined ultrasonic transducer (PMUT) array. Two PMUT arrays with a resonant frequency of 125 kHz are used as the sensitive elements of the ultrasonic gas flowmeter to realize alternate transmission and reception of ultrasonic signals. The sensor contains 5 × 5 circular elements with a size of 3.7 × 3.7 mm

Indexed as

MEMSPMUTs arrayPZTultrasonic flowmeter

Identifiers

PMID38258164
PMCPMC10821114

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.