Evidence map›Paper›PMID 38257676›Full record

ArticleSensors (Basel, Switzerland)2024

Exploring the Performance of an Artificial Intelligence-Based Load Sensor for Total Knee Replacements.

Samira Al-Nasser, Siamak Noroozi, Adrian Harvey, Navid Aslani, Roya Haratian

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
4.0field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Review
  3. AI classification of knee prostheses from plain radiographs and real-world applications.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Samira Al-NasserBournemouth University, Fern Barrow, Poole BH12 3BB, UK.ORCID 0009-0008-0175-8696
Siamak NorooziBournemouth University, Fern Barrow, Poole BH12 3BB, UK.
Adrian HarveyRoyal Bournemouth Hospital, Castle Ln E, Bournemouth BH7 7DW, UK.
Navid AslaniInnovid Tech Ltd., 107b Athenlay Road, London SE15 3EJ, UK.
Roya HaratianBournemouth University, Fern Barrow, Poole BH12 3BB, UK.
Bournemouth University · GBRoyal Bournemouth Hospital · GB

Funding

Zimmer Biomet (United Kingdom) Part of a PhD
6 · The paper itself

Abstract

Using tibial sensors in total knee replacements (TKRs) can enhance patient outcomes and reduce early revision surgeries, benefitting hospitals, the National Health Services (NHS), stakeholders, biomedical companies, surgeons, and patients. Having a sensor that is accurate, precise (over the whole surface), and includes a wide range of loads is important to the success of joint force tracking. This research aims to investigate the accuracy of a novel intraoperative load sensor for use in TKRs. This research used a self-developed load sensor and artificial intelligence (AI). The sensor is compatible with Zimmer's Persona Knee System and adaptable to other knee systems. Accuracy and precision were assessed, comparing medial/lateral compartments inside/outside the sensing area and below/within the training load range. Five points were tested on both sides (medial and lateral), inside and outside of the sensing region, and with a range of loads. The average accuracy of the sensor was 83.41% and 84.63% for the load and location predictions, respectively. The highest accuracy, 99.20%, was recorded from inside the sensing area within the training load values, suggesting that expanding the training load range could enhance overall accuracy. The main outcomes were that (1) the load and location predictions were similar in accuracy and precision (

Indexed as

Arthroplasty, Replacement, KneeArtificial IntelligenceHospitalsHumansKnee JointSoftwareartificial intelligenceintraoperative load measuringjoint force sensortotal knee replacement

Identifiers

PMID38257676
PMCPMC10821047
OpenAlexW4390945916

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.