ArticleSensors (Basel, Switzerland)2024
A Wide-Band Magnetoelectric Sensor Based on a Negative-Feedback Compensated Readout Circuit.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- A Positioning Alarm System for Explosive Impact Debris Protective Suit Based on an Accelerometer Array.Sensors (Basel, Switzerland) · 2024Article
- Magnetoelectric Sensor Operating inSensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Magnetoelectric (ME) sensors cannot effectively detect broadband magnetic field signals due to their narrow bandwidth, and existing readout circuits are unable to vary the bandwidth of the sensors. To expand the bandwidth, this paper introduces a negative-feedback readout circuit, fabricated by introducing a negative-feedback compensation circuit based on the direct readout circuit of the ME sensor. The negative-feedback compensation circuit contains a current amplifier, a feedback resistor, and a feedback coil. For this purpose, a Metglas/PVDF/Metglas ME sensor was prepared. Experimental measurements show that there is a six-fold difference between the maximum and minimum values of the ME voltage coefficients in the 6-39 kHz frequency band for the ME sensor without the negative-feedback compensation circuit when the sensor operates at the optimal bias magnetic field. However, the ME voltage coefficient in this band remains stable, at 900 V/T, after the charge amplification of the direct-reading circuit and the negative-feedback circuit. In addition, experimental results show that this negative-feedback readout circuit does not increase the equivalent magnetic noise of the sensor, with a noise level of 240 pT/√Hz in the frequency band lower than 25 kHz, 63 pT/√Hz around the resonance frequency of 30 kHz, and 620 pT/√Hz at 39 kHz. This paper proposes a negative-feedback readout circuit based on the direct readout circuit, which greatly increases the bandwidth of ME sensors and promotes the widespread application of ME sensors in the fields of broadband weak magnetic signal detection and DBS electrode positioning.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.