ReviewInternational journal of molecular sciences2024
Coatings for Cardiovascular Stents-An Up-to-Date Review.
Review in International journal of molecular sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed.
- Optimization of TX-100/SDS-based decellularized vascular material using ultrasound and chemical treatment: evaluation of structure and biosafety.Organogenesis · 2026Article
- Cardiovascular stent technologies for coronary and valvular heart disease: the potential of 3D printing for stent fabrication.Nature reviews. Cardiology · 2026Review
- Article
- Inkjet Printing of Drugs into Surface-Embedded Micro-Reservoirs for Drug-Releasing Implants: Influence of Solvent Properties on Deposition Behavior.Journal of functional biomaterials · 2026Article
- Polydopamine-Cu(II) Ions Functional Coatings on Zinc Wire: Surface Characterization and Degradation Behavior.ACS materials Au · 2026Article
- Review
- Mechanically Robust Biodegradable Stents With Theragenerative Vascular Responses via Combined 3D Printing and Janus Nanoengineering.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Antithrombotic Polymers: A Narrative Review on Current and Future Strategies for Their Design, Synthesis, and Application.International journal of molecular sciences · 2026Review
- Evolution of Coronary Stents: From Birth to Future Trends.Journal of clinical medicine · 2025Review
- Integrated Polymeric Sensors in Heart and Blood Vessel Monitoring: A Review.Sensors (Basel, Switzerland) · 2025Review
- Polymeric Composite Thin Films Deposited by Laser Techniques for Antimicrobial Applications-A Short Overview.Polymers · 2025Review
- Article
- Innovative Micro- and Nano-Architectures in Biomedical Engineering for Therapeutic and Diagnostic Applications.Micromachines · 2025Review
- Article
- Stent thrombosis: a contemporary guide to definitions, risk factors, and management.Frontiers in cardiovascular medicine · 2025Review
- Research Progress of Magnesium Alloys and Its Alloys in Medical Applications.International journal of general medicine · 2025Review
- Biofunctional coatings and drug-coated stents for restenosis therapy.Materials today. Bio · 2024Review
- Provinols™, a Polyphenolic Extract of Red Wine, Inhibits In-Stent Neointimal Growth in Cholesterol-Fed Rabbit.Pharmaceutics · 2024Article
- Application of PVD coatings in medical implantology for enhanced performance, biocompatibility, and quality of life.Heliyon · 2024Review
- Special Issue "Antimicrobial Biomaterials: Recent Progress".International journal of molecular sciences · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Cardiovascular diseases (CVDs) increasingly burden health systems and patients worldwide, necessitating the improved awareness of current treatment possibilities and the development of more efficient therapeutic strategies. When plaque deposits narrow the arteries, the standard of care implies the insertion of a stent at the lesion site. The most promising development in cardiovascular stents has been the release of medications from these stents. However, the use of drug-eluting stents (DESs) is still challenged by in-stent restenosis occurrence. DESs' long-term clinical success depends on several parameters, including the degradability of the polymers, drug release profiles, stent platforms, coating polymers, and the metals and their alloys that are employed as metal frames in the stents. Thus, it is critical to investigate new approaches to optimize the most suitable DESs to solve problems with the inflammatory response, delayed endothelialization, and sub-acute stent thrombosis. As certain advancements have been reported in the literature, this review aims to present the latest updates in the coatings field for cardiovascular stents. Specifically, there are described various organic (e.g., synthetic and natural polymer-based coatings, stents coated directly with drugs, and coatings containing endothelial cells) and inorganic (e.g., metallic and nonmetallic materials) stent coating options, aiming to create an updated framework that would serve as an inception point for future research.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.