The Impact of Dual and Triple Energy Window Scatter Correction on I-123 Postsurgical Thyroid SPECT/CT Imaging Using a Phantom with Small Sizes of Thyroid Remnants.

Konstantinos Michael, Savvas Frangos, Ioannis Iakovou, Antonis Lontos, George Demosthenous, Yiannis Parpottas

Open access · goldAbstract read
In one paragraph

Article in Life (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Scatter correction for self-collimating SPECT using a 3D U-Net framework.American journal of nuclear medicine and molecular imaging · 2026
    Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Konstantinos MichaelDepartment of Mechanical Engineering, Frederick University, Nicosia 1036, Cyprus.ORCID 0000-0002-0954-3293
Savvas FrangosDepartment of Nuclear Medicine, Bank of Cyprus Oncology Center, Nicosia 2006, Cyprus.ORCID 0000-0002-1512-7480
Ioannis IakovouSchool of Medicine, Aristotle University of Thessaloniki, 54621 Thessaloniki, Greece.ORCID 0000-0003-2101-3954
Antonis LontosDepartment of Mechanical Engineering, Frederick University, Nicosia 1036, Cyprus.
George DemosthenousDepartment of Mechanical Engineering, Frederick University, Nicosia 1036, Cyprus.
Yiannis ParpottasDepartment of Mechanical Engineering, Frederick University, Nicosia 1036, Cyprus.ORCID 0000-0001-6177-3734
Frederick University · CYAristotle University of Thessaloniki · GRBank of Cyprus Oncology Center · CY

Funding

European Regional Development Fund and the Republic of Cyprus EXCELLENCE/1216/0088
6 · The paper itself

Abstract

I-123 is preferential over I-131 for diagnostic SPECT imaging after a thyroidectomy to determine the presence and size of residual thyroid tissue for radioiodine ablation. Scattering degrades the quality of I-123 SPECT images, primarily due to the penetration of high-energy photons into the main photopeak. The objective of this study was to quantitatively and qualitatively investigate the impact of two widely used window-based scatter correction techniques, the dual energy window (DEW) and triple energy window (TEW) techniques, in I-123 postsurgical SPECT/CT thyroid imaging using an anthropomorphic phantom with small sizes of remnants and anatomically correct surrounding structures. For this purpose, non-scatter-corrected, DEW and TEW scatter-corrected SPECT/CT acquisitions were performed for 0.5-10 mL remnants within a phantom, with 0.5-12.6 MBq administered activities within the remnants, and without and with background-to-remnant activity ratios of 5% and 10%. The decrease in photons, the noise and non-uniformity in the background region due to scatter correction were measured, as well as the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) from small remnants. The images were also visually evaluated by two experienced nuclear medicine physicians. Scatter correction decreased photons to a higher extent in larger regions than smaller regions. Larger remnants yielded higher SNR and CNR values, particularly at lower background activities. It was found from the quantitative analysis and the qualitative evaluation that TEW scatter correction performed better than DEW scatter correction, particularly at higher background activities, while no significant differences were reported at lower background activities. Scatter correction should be applied in I-123 postsurgical SPECT/CT imaging to improve the image contrast and detectability of small remnants within the background.

Indexed as

nuclear imagingpostsurgical diagnostic thyroid imagingthyroid phantomthyroid remnants

Identifiers

PMID38255728
PMCPMC10821084
OpenAlexW4390741616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.