Evidence map›Paper›PMID 38255361›Full record

ReviewChildren (Basel, Switzerland)2023

Diagnostic Accuracy of Physical Examination and Pulse Oximetry for Critical Congenital Cardiac Disease Screening in Newborns.

Jari T van Vliet, Naizihijwa G Majani, Pilly Chillo, Martijn G Slieker

Open access · goldAbstract readReview
In one paragraph

Review in Children (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Jari T van VlietDepartment of Pediatric Cardiology, Wilhelmina Childrens Hospital, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands.ORCID 0009-0005-7969-2859
Naizihijwa G MajaniDepartment of Pediatric Cardiology, Wilhelmina Childrens Hospital, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands.
Pilly ChilloDepartment of Internal Medicine, School of Medicine, Faculty of Adult Cardiology, Muhimbili Campus, Muhimbili University of Health and Allied Sciences, Dar es Salaam 65001, Tanzania.
Martijn G SliekerDepartment of Pediatric Cardiology, Wilhelmina Childrens Hospital, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands.ORCID 0000-0001-8198-511X
University Medical Center Utrecht · NLMuhimbili University of Health and Allied Sciences · TZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNewborns with a critical congenital heart disease left undiagnosed and untreated have a substantial risk for serious complications and subsequent failure to thrive. Prenatal ultrasound screening is not widely available, nor is postnatal echocardiography. Physical examination is the standard for postnatal screening. Pulse oximetry has been proposed in numerous studies as an alternative screening method. This systematic review and meta-analysis aims to determine the diagnostic accuracies of both screening methods separately and combined.

methodsA systematic literature search of the Embase, PubMed, and Global Health databases up to 30 November 2023 was conducted with the following keywords: critical congenital heart disease, physical examination, clinical scores, pulse oximetry, and echocardiography. The search included all studies conducted in the newborn period using both physical examination and pulse oximetry as screening methods and excluded newborns admitted to the intensive care unit. All studies were assessed for risk of bias and applicability concerns using the QUADAS-2 score. The review adhered to the PRISMA 2020 statement guideline.

resultsOut of 2711 articles, 20 articles were selected as eligible for meta-analysis. Cumulatively, the sample included 872,549 screened newborns. The pooled sensitivity of the physical examination screening method was found to be 0.69 (0.66-0.73 (95% CI)) and specificity was found to be 0.98 (0.98-0.98). For the pulse oximetry screening method, the pooled sensitivity and specificity yielded 0.78 (0.75-0.82) and 0.99 (0.99-0.99), respectively. The combined method of screening yielded improved diagnostic characteristics at a sensitivity and specificity of 0.93 (0.91-0.95) and 0.98 (0.98-0.98, respectively.

conclusionsThe evidence indicates that combining both physical examination and pulse oximetry to screen for critical congenital heart disease exceeds the accuracy of either separate method. The main limitation is that solely newborns with suspected critical congenital heart disease were subjected to the reference standard. We recommend adapting both methods to screen for critical congenital heart diseases, especially in settings lacking standard fetal ultrasound screening. To increase the sensitivity further, we recommend increasing the screening time window and employing the peripheral perfusion index.

Indexed as

critical congenital heart diseasenewborn screeningpulse oximetry

Identifiers

PMID38255361
PMCPMC10814555
OpenAlexW4390437008

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.